ORBIT FR Clean Room RF Absorbers - AEP-X-CR Series User Manual

Page 2

Advertising
background image

26

1/

Description

AEMI CR1 Clean Room RF Absorbers have a clear latex
coating that completely covers the absorber, including
the bottom. They are treated for use in class 100,000
clean room environments. This treatment does not ne-
gatively affect the overall performance. These absorbers
are used extensively in satellite assembly facilities as well
as other aerospace applications.

AEMI CR2 Clean Room RF Absorbers have a rubberized
treatment that completely covers the absorber, including
the bottom. They are treated for use in class 10,000
clean room environments. This treatment does not ne-

gatively affect the overall performance. These absorbers
are used extensively in satellite assembly facilities as well
as other aerospace applications.

2/

Unique Manufacturing Process

After the standard manufacturing process, these ma-
terials undergo further treatment to remove any loose
debris from the manufacturing process. The material is
coated with a special latex binder or plasticized coating
(depending on class).

3/

Specifi cations

AEP-4-CR AEP-6-CR AEP-8-CR AEP-12-CR AEP-18-CR AEP-24-CR AEP-36-CR

AEP-48-CR

Height in

4 6 8 12 18 24 36

48

cm

10.2

15.2

20.3

30.5

45.7

61

91.4

121.9

Pyramids

per block

144

64 64 36 16 9 4 4

@ 125 MHz dB

28

@ 250 MHz dB

30

32

35

@ 500 MHz dB

30

35

37

40

@ 1.0 GHz

dB

30

35

37

40

42

45

@ 3.0 GHz

dB

30 33 37 40 45 45 50

50

@ 6.0 GHz

dB

35 37 45 45 50 50 50

50

@ 10.0 GHz dB

40 40 50 50 50 50 50

50

@ 13.0 GHz dB

45 50 50 50 50 50 50

50

@ 15.0 GHz dB

50 50 50 50 50 50 50

50

Power

Watt/in

2

0.5 0.5 0.5 0.5 0.5 0.5 0.5

0.5

Watt/m

2

775 775 775 775 775 775 775

775

Weight lbs/pc.

2.5

3 4.5

6 9 13.5

18.5

25

kg/pc.

1.1

1.4

2

2.7

4.1

6.1

8.4

11.3

Absorption @ Normal Incidence

AEP-6-CR mechanical drawing

6”

1”

2”

24”

24”

Advertising