Model lkm, Lkm marine clutch application information, Iin np pu utt p pa arra am me ette errs s – Wichita Clutch LKM Clutch User Manual

Page 6

Advertising
background image

45

I N D U S T R I A L C L U T C H P R O D U C T S

Model LKM

LKM Marine Clutch Application Information

The selection chart on the previous page is suitable for
forward/reverse main propulsion service at 125 PSI
actuation.

For controllable pitch propellers, dredge pumps, winches,
and fire pumps use the following service factors.

Example: Centrifugal dredge pump Disconnect clutch
application.

IIn

np

pu

utt P

Pa

arra

am

me

ette

errs

s

The engine is rated 3000 HP and the shaft the clutch is to
be mounted on is rotating at 900 RPM. The available air
pressure is 150 PSIG.

The Model LKM-225-B (rated at 510,000 LB-IN) is selected
from the static torque column shown in the operational data
chart on the previous page. This unit is the nearest size that
meets or exceeds the value of 437,674 LB-IN required.

The allowable speed for the Model LKM-225-B is 1200 RPM
and exceeds the operating speed of 900 RPM. The selection
is appropriate from a torque and speed standpoint.

Dredge pumps can draw extraneous matter into the pump
which may suddenly stall the pump impeller. This places a
huge shock on the drive system and the clutch is called
upon to act as a fuse in these instances. A review of the
magnitude of the actual applied service factor is always
required to be certain the drive system components can
withstand these overloads. It may be necessary to reduce
the clutch service factor which increases the likelihood of
clutch damage but saves a more costly drive system repair.

The preferred way to reduce the service factor is to adjust
the operating air pressure accordingly and maintain the
clutch size as originally selected.

The following procedure may be used to calculate the air
pressure required for any desired service factor. In this
example, the recommended service factor was 2.5. We
selected a Model LKM-225-B clutch since it was the closest
unit that met or exceeded the calculated torque requirement
of 437,674 LB-IN. Note that the actual service factor is 2.91.

If, by way of example, it was decided that a service factor
of 2.0 was required, the supply air pressure should be set at
103 PSI.

To summarize, a Model LKM-225-B operating at 103 PSIG
will provide a 2.0 service factor for this application.

Tact = Actual Static Capacity = Cat. Stat. Rating x

Supply Press

Rated Press

Tact = 510000 x = 612000 LBIN

150

125

Actual Serv. Fact. = = = 2.91

Tact

Working Torq

612000

210083

Operating Pressure =

125 x Reqd. Serv. Fact. x Work Torq

Cat. Stat. Torq. Rating

Operating Pressure = = 103 PSIG

125 x 2.0 x 210083

510000

Working Torque = = = 210083 LBIN

HP x 63025

RPM

Minimum Static Torque = Work Torque x Service Factor

= 210083 x 2.5 = 525208 LBIN

3000 x 63025

900

Minimum Catalogue Rating = Static Torque Reqd x

Rated Press

Supply Press

Minimum Catalogue Rating = 525208 x = 437674 LBIN

125

150

Service

Machinery

Factor

Main Propulsion

1.8

Cont. Pitch Prop.

Winches, Centrifugal

1.65

Fire Pumps

Centrifugal Dredge Pumps

2.5

Main Propulsion Continuous

Consult

Slip from Engine Idle

Factory

Advertising