1. Thaw a bottle of Coliscan MF overnight at room temperature. (2 mL of Coliscan

MF is required for each sample to be tested). Bottles may also be thawed for
same day use by standing the bottles in warm water until the contents become
liquid.

Sample Collection and Dilution

2. Collect the water sample according to the chart below.

Environmental

river, lake, pond, stream, ditch 1.0 to 5.0 mL

Drinking water

well, municipal, bottled

100 mL

Generally, use 100 mL for samples suspected of having very low coliform levels such
as drinking water. Use 1.0 to 5.0 mL for samples suspected of having moderate
amounts of coliform, such as environmental samples (rivers, ponds, streams, lakes or
ditches). Samples that are less than 10 mL will need to be diluted with 10 – 20 mL of
a sterile diluent before filtering.

For optimum results, the sample should be collected within two hours before filtering.
If this is not possible, the sample may be refrigerated or kept on ice for up to 24
hours.

3. Use a permanent marker or wax pencil to

label a dish with pad with the sample information.

4. Use the sterile 3 mL dropper to add 2mL of

Coliscan MF to the pad in the dish. Cover the
dish with a lid.