TECHNICAL ISSUE

CAUSE

SOLUTION

Starts with doors open

Faulty #1 micro switch (start/stop)

Replace micro switch, P/N 00411.00

Faulty door switch

Replace switch, P/N 00557.55

Faulty #1 micro switch (start/stop)

Replace micro switch, P/N 00411.00

Continues cycle

Faulty start/fill switch

Replace switch, P/N 00421.40

Faulty door switch

Replace door switch, P/N 00557.55

Wash motor will not shut off

Delimer switch in wrong position

Switch to

NORMAL

position

Faulty motor contactor

Replace contactor, P/N 00404.82

Faulty # 6 micro switch

Replace micro switch, P/N 00411.00

Sanitizer pump does not run

Delimer switch in wrong position

Switch to

NORMAL

position

Faulty sanitizer pump motor

Replace sani motor, P/N 00416.00

Debris inside water solenoid valve

Clean and replace diaphragm, P/N
00706.00


Water solenoid leaking

High water pressure on supply line

Decrease water pressure

Faulty water solenoid valve

Replace valve, P/N 00705.00

Leaking drain ball

Replace drain ball, P/N 00121.00

Does not fill or hold water in tank

Faulty #4 micro switch (Fill)

Replace micro switch, P/N 00411.00

Debris inside water solenoid valve or
Faulty valve

Clean and replace diaphragm/valve,
, P/N 00706.00, P/N 00705.00

Worn internal vac. Brkr parts

Replace or clean parts, P/N

00735.00

Faulty check valve

Replace check valve, P/N 00715.00

Vacuum breaker leaks

Low incoming water pressure

Increase water pressure

Only runs when start/fill switch is
depressed

Faulty #1 micro switch (start/stop)

Replace micro switch, P/N 00411.00

Faulty Door switch

Replace door switch, P/N 00557.55

Will not start/ nothing works

Wall breaker tripped

Reset breaker

Master on/off switch on machine turned
off, or faulty

Reset or replace master switch, P/N
00433.00

Faulty #2 Micro switch (cycle reset)

Replace micro switch, P/N 00411.00

Runs, but none of the other functions
engage

Faulty ice cube relay (yellow relay)

Replace relay, P/N 00631.00

Faulty motor contactor

Replace contactor, P/N 00404.82











Advertising