Installation, Operation – Campbell Hausfeld HU500000 User Manual

Page 5

Advertising
background image

5

HU500000, HU502000

www.chpower.com

Installation

lOCatIOn
It is extremely important to install the
compressor in a clean, dry, and well
ventilated area. The compressor must
be placed on a firm, level surface where
the surrounding air temperature will
not be more than 100°F.
A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could obstruct
air flow.

Do not locate the

compressor air inlet

near steam, paint spray, sandblast areas
or any other source of contamination.
This debris will damage the motor.

eleCtrICal InStallatIOn

All wiring

and

electrical connections should
be performed by a qualified
electrician. Installation must
be in accordance with local codes and
national electrical codes.

WIrInG
1. Local electrical wiring codes

differ from area to area. Source
wiring, plug and protector must
be rated for at least the amperage
and voltage indicated on motor
nameplate, and meet all electrical
codes for this minimum.

2. Use a slow blow fuse or a circuit

breaker.

3. This product is for use on a

nominal 120 volt circuit and has
a grounding plug that looks like
the plug illustrated in Figure 6.

Make sure the product is connected
to an outlet having the same
configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire
for electric current. This product
is equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be
plugged into an outlet that is
properly installed and grounded in
accordance with all local codes and
ordinances.

Overheating, short

circuiting and fire

damage will result from inadequate
wiring.

TEST

RESET

Figure 6 - Grounding Method

Grounded Outlet

Grounding Pin

Operation

beFOre FIrSt Start-Up
break-In prOCeDUre
(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to repeat.)
1. Open drain valve located on bottom

of tank.

2. Turn On / OFF switch to OFF

position.

3. Plug in power cord.
4. Turn On / OFF switch to On position

and run compressor for 30 minutes.

5. Turn On / OFF switch to OFF

position.

6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.

OperatInG prOCeDUre
1. Turn switch to OFF position and plug

in power cord.

2. Turn regulator knob

counterclockwise to close air flow.

3. Turn switch to aUtO position.
4. Compressor will build to maximum

pressure and shut off.

5. With hose attached to outlet of

compressor, attach tire chuck or
other tool to open end of hose.

6. Adjust regulator to proper pressure

for tool or tire. Operate tool per
instructions.

As air is depleted from the tank by
use of a tire chuck, tool, etc., the
compressor will restart automatically
at its preset “cut-in” pressure. When
a tool is being used continuously,
the compressor will cycle on and off
automatically.
7. Turn switch to OFF position, unplug

power cord and drain tank of air
when finished using compressor.

Minimum Gauge of Extension Cord

25 ft.

50 ft.

100 ft.

14

12

10

Use of an extension cord may cause excess
heat to motor. This could lead to tripped
breaker (at electrical panel) or tripped
thermal overload (on compressor motor).
If this occurs, eliminate extension cord and
plug compressor directly into electrical
outlet. Avoid using extension cords; use
longer air hose(s) instead.