Caution, Instructions for installing sargent – SARGENT 8800 Rim Exit Device User Manual

Page 2

Advertising
background image

Mark vertical and horizontal
reference lines on the door

Identify type of installation to
determine location or vertical CL

Horizontal
reference line
(C of chassis and
rail assembly)

L

Horizontal
reference line
(C of mounting
holes)

L

Vertical
reference line
(C of chassis)

L

Prepare Door

Tape template on inside of door

along reference lines.
Spot and drill holes.

Vertical

reference line

(C of chassis)

L

Horizontal reference line

(37-5/8" from finished floor

for 41" height center of

push rail.)

Vertical reference

line (C of chassis)

L

Vertical reference

line (C of chassis)

L

Single Door (Non-Fire Rated)

Double Door with 980 Mullion

Single Door (12- Fire Rated Exit Device)

Double Door with 12-980 Mullion

For 649 strike Dim. “A” = 2-1/4"

For 613 strike Dim. “A” = 1-3/4"

For 642 strike Dim. “A” = 1-1/2"

Door

Door

Vertical reference

line (C of chassis)

L

Door

Door

Door

649 Strike

649 Strike

649 Strike

Apply Hardware

1. Attach chassis to

door with (4) #10

mounting screws.
2. Through-bolt outside

trim and cylinder

to chassis, if used.

Mount SARGENT cylinder

with (2) screws thru chassis

Chassis

mounting

screw

Cylinder

mounting

screw

Apply Covers and Strike

Attach cover to chassis with

four (4) cover screws

Attach end cap to

mounting plate with

two cover screws

649 Strike (for Fire Rated

application) – attach with (2)

outer screws and adjust for

proper position. Drill and tap

thru strike two holes in frame

and fasten strike in place with

(2) inner screws

Apply Rail Assembly

Determine cut off dimension “X” by

subtracting 1-3/4" from dimension “Y”.

Mark cut off point on mounting rail.

For doors with stile

rail must overlap stile

by 1/2" min.

Vertical reference line

(C of chassis)

L

1-3/4" Min.

Cut off on mark

and deburr

Depress arm into rail opening and slide

rail onto chassis.

Level rail and fasten mounting plate.

Arm

Level

Mounting plate

Attach rail assembly to the

chassis with two #8 truss

head machine screws

Place mounting plate tight

against rail and attach it

to the door with three #10

round head screws

• Check box label for rail size and refer

to chart for door sizes. If cutting is not

required, proceed to step “B”.
• If cutting is required, continue

with step “A”.

CAUTION!

Before Starting:

– Install mullion if used;
– Door should be fitted and hung;
– Check box label for size of exit device.
Available Stock Lengths:
Length “E”: 32" door, no cut off required.

Can be cut to fit doors down to 24" wide.
Length “F”: 36" door, no cut off required.

Can be cut to fit doors down to 33" wide.
Length “J”: 42" door, no cut off required.

Can be cut to fit doors down to 37" wide.

Length “G”: 48" door, no cut off required.

Can be cut to fit doors down to 43" wide.

For Assistance, contact SARGENT at 800-727-5477 or www.sargentlock.com

IMPORTANT:

Surface of the door where exit device

is applied must be flush.

Clear away any raised projections

to allow exit device to rest on

flat surface of the door.

US Patent No. 268003

Canadian Patent No. RD1981

Rim cylinder

649 Strike

shown

Center chassis

assembly

Cover

Collar

Mortise

cylinder

Rail assembly

“Lock Down Key”
To operate: Depress pushrail;

insert hex key and turn clockwise.

Mounting

bracket

End
cap

Finished Floor

Vertical reference line

(C of chassis)

L

A6703G 3/12

649 Strike (for non-Fire Rated

application) – attach with

(2) strike screws and two

lock washers

INSTRUCTIONS FOR INSTALLING SARGENT

®

8816 AND 12-8816 SERIES RIM EXIT DEVICES

Copyright ©2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction

in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

Advertising