8 specifications – Crown Audio MA-1202 User Manual

Page 24

Advertising
background image

Operation Manual

MA Series Power Amplifiers

page 24

Figure 8.2 Macro-Tech 1202 Maximum Power Matrix

8 Specifications

Maximum Power Notes:
All maximum power specifications are based on
0.1% regulated AC mains and an ambient room
temperature of 70°F (21°C). International units
with multi-tap transformers are specified for the
best-case transformer tap (normally 240 VAC, 60
Hz). Although it is an unusual condition, your
amplifier can function well with AC mains volt-
ages up to 10% over the specified line voltage.
With overvoltage conditions, your amplifier may
be capable of delivering instantaneous power
levels up to 20% greater than the specifications
in the matrix.

1. A single cycle sine wave is presented to the
amplifier and monitored for nonlinear distortion.
The average power during the burst is reported.
Loudspeakers must be able to withstand this
level if they are to be safely used with this ampli-
fier.

2. A 40-millisecond sine wave burst (10% duty
cycle) is presented to the amplifier and moni-
tored for nonlinear distortion. The average power
during the burst is reported. This power level is a
measurement of the amplifier’s maximum tran-
sient power than can be perceived by the human
ear.