Device IDs

Once your expansion bus connections are made (and if you have more than one

XAP 800 at a site), you need to set up a unique expansion bus device ID number—a

network address—for each XAP 800 on the network. As shipped from the factory, all

XAP 800s are set to device ID 0.

To assign device IDs

1.

Press the front-panel Enter button, then scroll through the menu until the

System menu is visible.

2.

Press

Enter, then scroll through the menu until Device ID is visible.

3.

Press Enter, then scroll through the eight (0–7) options. When the desired

device ID is visible, press Enter to select it. (You can also set the device ID in

the Unit Properties window of G-Ware software see page 25.)

4.

Repeat this process for each XAP 800 on the expansion bus network.

Mixer mode

There are two mixer mode settings: slave (default) and master. A master unit is not

required in a networked system and in most installations, all units will be slaves.

Master units ignore audio from upstream units. This prevents audio from being

received from units above the master unit in the network. However, global control of

the system is still maintained by whichever XAP 400/800 or PSR1212 unit is

connected to a control device through its RS-232 or RS-485 ports. Control is not

affected by master/slave designations.

In Figure 2.5, the third unit in the network is a master. It prevents the audio

from the first and second units from being passed down the network chain.

Likewise the second master unit in the network will not pass on the audio from the

unit before it. The third unit provides system-wide control through a connection to

its RS-232 port.

To select a mixer mode

1.

Press the front panel Enter button and scroll through the menu until System

menu is visible. Press Enter to select the menu.

2.

Scroll through the System menu and select Mixer Mode.

3.

Select the mixer setting you want to use.

Repeat for additional units.

If the same device ID is

assigned to more than one

unit on the E-bus network,

the Meter LED “+12” will flash

red, the Mic LEDs “1,” “2,” “4,”

and “8” will flash green on the

affected units. To correct the

problem, change the device ID on

one of the conflicting units.

✍ ✍

Figure 2.5. E-bus network with master units

You can also use G-Ware

to select a mixer mode.

See page 25.

✍ ✍

Advertising