Monarch Instrument Nova-Strobe vbx User Manual

Page 4

Advertising
background image

4.4 Tachometer Mode - External Input Required ............ 11
4.5 External Delay Modes (Phase Shifting) .................... 12
4.6 Lock Modes - Accelerometer Input Required .......... 12
4.7 Power Up Features .................................................... 14

5.0 APPLICATIONS .................................................................... 15

5.1 Using the Stroboscope to Measure RPM ................. 15
5.2 Balancing and Phase Measurement ......................... 17
5.3 Phase Analysis ........................................................... 19
5.4 Motion Studies ............................................................ 21

6.0 LIMITATIONS OF REMOTE OPTICAL SENSORS .................. 22

7.0 LAMP AND FUSE REPLACEMENT ....................................... 23

7.1 Lamp Replacement .................................................... 23
7.2 Fuse ............................................................................. 25

8.0 BATTERY AND POWER SUPPLY SPECIFICS ....................... 25

8.1 Low Battery Indication ............................................... 26
8.2 Charging the Batteries ............................................... 26
8.3 External Power Supply/Recharger ............................ 27
8.4 Battery Disposal ......................................................... 27

9.0 SPECIFICATIONS .................................................................. 28

10.0 OPTIONS AND ACCESSORIES ............................................ 30

General:
Time Base

Ultra Stable Crystal Oscillator

Display

LCD display with 6 numeric 0.506 inch [12.85 mm] high
digits and 5 alphanumeric 0.282 inch [7.17 mm] high digits

Indicators

Battery level, On Target, TIME, AUTO, ALT, TACH, LOCK,
and EXT icons

Knob Adjustment

Digital Rotary switch with 36 detents per revolution;
velocity sensitive

Memory

Last setting before power down is remembered and
restored on next power up. 9 user settable flash rates.

Output Pulse

40 µsec positive/negative pulse (menu selectable),
3.3 Vdc typical

Input Power

Internal Rechargeable Batteries 6 Vdc, External AC
recharger (115 Vac to 230 Vac)

Light Output

Average: 11 Watts at 3000 FPM, >13 Watts above
3450 FPM
Instantaneous (per flash): 230 mJoule typical to
3450 FPM

Flash Duration

10-25 microseconds (auto adjust with flash rate)

Flash Tube (Lamp) Life 100 million flashes
Run Time

2 hours typical at 1800 FPM, and over 1 hour at
6000 FPM with fully charged batteries

Charge Time

4-5 hours typical with PSC-pbxU

Weight

1.875 lbs [0.8505 kg] including batteries

This product is designed to be safe for indoor use under the following
conditions (per IEC61010-1).

Operating Temperature 32-104 ºF [0-40 °C]
NOTE: Safety thermal feature will set unit into TACH Mode (stops

flashing) in the event of internal overheating.

Humidity

Maximum relative humidity 80% for temperature up to 88 °F [31
°C] decreasing linearly to 50% relative humidity at 104 °F [40 °C]