0 specifi cations – Monarch Instrument Pocket LED Strobe User Manual

Page 21

Advertising
background image

17

6.0

Specifi cations

Internal Mode:
Flash Range

30 to 300,000 FPM (Flashes Per Minute), 0.5 to
5000Hz

Flash Rate Accuracy

0.005% of setting or ± last digit

Flash Rate Resolution

0.01 to 1 FPM (menu selectable), 0.1 FPM resolution
above 9,999.99 FPM, 1 FPM resolution above
99,999.9

Display Update Rate

Instantaneous

External Modes:
Flash Range

0 to 300,000 FPM (Flashes Per Minute), 0 to 5000Hz

Tachometer Mode

30 to 300,000 RPM

Accuracy

±0.005% of reading up to 250,000 or ± last digit

Display Update Rate

0.5 second typical above 120 RPM

Trigger to Flash Delay ~ 15 µsec
External Input:

2.5V to 12V peak pulse 500 nanosec min pulse width,

Positive or Negative edge triggered (menu
selectable)

Output Pulse

3V pulse. One pulse per fl ash in internal mode.
Mimics input pulse in external mode.

Pulse In to Out Delay

< 0.2 µsec (External Mode)

Time Base

Ultra Stable Crystal Oscillator

Display

LCD display with 6 numeric 0.506 inch [12.85 mm]
high digits and 5 alphanumeric 0.282 inch [7.17 mm]
high digits

Indicators

Low Battery, On Target, Select, TACH, and EXT icons

Memory

Last setting before power down is remembered and
restored on next power up. 5 user settable memory
locations