Rev: 0.92 06/22/11

Protection

The data Logger comes with a rubber boot that can be installed to protect the USB
connector and provide some degree of bump and splash protection. The unit should
have the boot installed when traveling. The button can be operated when the boot is
in place. The boot cannot be fitted when analog modules are attached. The unit
should not be immersed in liquid.

Track-It

TM

Software

The Track-It

TM

PC Software allows the data logger to be programmed, allows the data to be retrieved, displayed, saved to disk or

exported to Excel

TM

. Data can also be displayed in real time (on devices using internal sensors). The software has both simple and

advanced modes for programming data loggers. Some of the features are:

• Delayed recordings, fixed duration recordings by time or number of samples, multiple record times, manual record by button

press, record on alarms.

Sample rates from 2 seconds to 24 hours. Instantaneous, average, maximum or minimum values.

Two Alarms, high or low, latched or momentary and record under these alarm conditions

Input scaling and offset for analog modules. Engineering unit selection for internal sensors.

Button function - record off/on, status indication, reset alarm indication.

Display of data graphically, digitally or tabular formats with alarm indication.

Export user selected data in Excel

TM

or CSV formats. Filter data to be exported.

Simple setup (single screen) or advanced mode.

Replacing the Battery

To replace the battery - loosen the two screws on the back of the Logger and remove the bottom case half. Caution - the screws have
small plastic washers. There are two battery options. Replace the relevant battery then replace the cover and the screws.

Option 1 - Coin Cell CR2032 3.0V

Option 2 - Lithium Thionyl Chloride EF651625 3.6V (LTC-7PN)