Of clutches 3 – Great Plains YP3025-24TR 25 Series 24 Twin Row 30 Inch Quick Start User Manual

Page 3

Advertising
background image

Quick Setup Guide for IntelliAg Model YP30 30” Twin Row

11001-1550-201002

©2010 DICKEY-john Corporation
Specifi cations subject to change without notice.

TABLE E:

Speed Set

Default Value

or Value to

Enter

Instructions/Defi nitions

Source

Digital Frequency

Select CAN Ground if radar is connected to ISO tractor cab harness.

Select Digital Frequency if radar or hall-effect is connected to WSMT

actuator harness.

Gspd Constant

12192

Input based on pulse count produced by the ground speed sensor

over 400’ distance. See Operator’s manual for calibration instructions.

Shutoff Speed

0.5 mph

Set desired minimum ground speed allowed before the system shuts

off.

Minimum

Override

2.0 mph

Set to operate when actual ground speed falls below the designated

value. Control will operate at this speed until actual ground speed

rises above minimum override speed or actual speed drops below

shutoff.

Master Sw

Timeout

10

Set to desired number of seconds system shuts off if the master

switch is turned on and there is no ground speed. Toggle master

switch to restart the system and turn off alarm.

Gspd Fail Alarm

Delay

5

Set to desired number of seconds alarm sounds after the ground

speed is zero and seed fl ow continues. (Monitor only)

Precharge

Ground Speed

0

Set to the desired speed the system will use when a precharge time

has been enabled for a control channel. Refer to Table C1: Planter

Control Setup for Precharge Time. This setting will only display when

a Precharge Time has been entered.

Implement Lift

Enabled

Implement lift switch, when enabled, displays an implement lift indica-

tor on the Main Work screen indicating implement lift position as up

or down. Control channels can be turned on and off without using the

master switch.

3

STEP 8: Speed Set Calibration Setup

At the Main Work screen, press the Speed Set button

.

Enter desired values using Table E as reference.
Press the Work Screen button

when ground speed calibration confi gura-

tions are complete to return to the Main Work screen.

1.
2.
3.

TABLE F:

Accessory

Setup

Default Value

or Value to

Enter

Instructions/Defi nitions

Hopper Setup

# of Hoppers

1 (base unit)

1 more (optional)

# of hopper sensors connected to each module (4 sensors maximum).

# of hopper data items for each listed module and the Hopp #’s value

will automatically populate if Auto Confi g is used to confi gure installed

sensors.

Logic Level

Active Lo

Sets the active state to low signifying that an alarm is generated if the

sensor’s output is in a low state. Use this setting if the connected sen-

sor outputs a low condition when empty similar to the DICKEY-john

hopper sensor.

Alarm Delay

5 sec

Controls the delay time between the detection of a high/low hopper

alarm condition and the generation of the resulting alarm. The value is

entered in seconds.

Channel

Assigns hopper sensor to channel.

RPM Setup

High Alarm

(fan speed)

4200 rpm

Sets the RPM value at which a high RPM warning error is generated.

Low Alarm

(fan speed)

2900 rpm

Sets the RPM value at which a low RPM warning error is generated.

High Alarm Delay

10 sec

Establishes the delay between the detection of a high RPM alarm

condition and the resulting alarm display. The value is entered in

seconds.

Low Alarm Delay

10 sec

Establishes the delay between the detection of a low RPM alarm

condition and the resulting alarm display. The value is entered in

seconds.

RPM Constant

3 pulses/rev

Number of pulses per sensor revolution.

RPM Filter

0

Filters the signal out of the RPM sensor.

Disable Control

on Low Alarm

Disabled

Allows for disabling of all control channels if the RPM value of the

selected sensor falls below the low alarm level setting.

STEP 9: Accessory Sensor Setup

Hopper Assignment

At the Main Work screen, press the Next Page button

.

Press the Module Confi guration button

to display the Module Confi gura-

tion screen.
At the Module Confi guration screen, press the Hopper Assign button

.

Press Hopper Set button

.

Enter desired values using Table F as reference.

RPM Assignment

At the Module Confi guration screen, press the Accessory Assignment button

.

Press the RPM Setup button

. NOTE: There must be at least 1 RPM sen-

sor confi gured before the RPM Setup button appears on the screen.
Enter desired values using Table F as reference.

1.
2.

3.
4.
5.

6.

7.

8.

STEP 10: Clutch Folding Module (CFM) Setup

The CFM is installed in the cab to control row clutches, marker, fold, fertilizer on/off,
lift and hitch.

At the Main Work screen, press the Clutch CFG button to access the Clutch
Confi guration screen and verify that the correct # of clutches are confi gured for
the system.
The Clutch CFG button

only appears as a top level button when a planter

output module and clutch folding module are installed.

1.

2.

O U T P U T

1 - 8

# O F
R O W S

R O W
# ’s

9 - 1 6

1 7 - 2 4

LEFT

CENTER
RIGHT

8

8

8

# of Clutches 3

Advertising
This manual is related to the following products: