Reading a seed rate chart, Barley (2 of 3) – Great Plains 3S-5000HDF Material Rate User Manual

Page 8

Advertising
background image

6

00/00HD Min-Till Folding Drill

Table of Contents

Main Box Rates

Great Plains Manufacturing, Inc.

195-325B

Table of Contents

Main Box Rates

2012-06-04

11. Divide the net seed weight by three. Multiply by

number of openers on your drill to determine the
total of pounds-per-acre seeded.

12. The Seed Rate Handle scale is a percentage of

meter opening, and is quite linear near scale center.
Calculate a new scale setting based on the test.

Note: You may want to repeat calibration procedure if

your results varied greatly from the Seed Rate
Chart, or if you must operate near the ends of the
Seed Rate handle scale (0-20 or 90-100).

13. Set the center and right drill sections to match the

now-calibrated left section.

14. With calibration complete, Reinstall fertilizer chain (if

removed), reconnect seed hoses, and lower gauge
wheel to ground.

When drilling, check seeding rate by noting acres drilled,
amount of seed added to drill and seed level in drill box.
If you are seeding more or less than desired, adjust rate
slightly to compensate for field conditions.

Reading a Seed Rate Chart

Charts in U.S. customary units begin on page 8.
Metric charts begin on page 25.

1.

Find your seed. Charts are in alphabetical order by
seed name. Charts covering more than one seed
may be out of order.
For Rape, see Alfalfa.
For Sudan, see Flax.

This example presumes we desire to plant Barley at
48 pounds per acre with a 7.5 inch drill.

There are multiple charts for some seeds, and the
rates may overlap. Use the chart where your desired
rate is closest to 50 on the Seed Rate Handle scale.

In our example, that would be Barley chart 2 of 3.

If your seed is not listed, find one with similar size,
shape and density. Density of the test seed used to
develop the chart appears under the right end of the
handle scale values.

For example:
on the 63-row 7.5 inch drill:

54.6 lbs/ac

54.6

2.6

3

------

63

×

=

MeasuredRate

NetWeight

3

-------------------------

OpenerCount

×

=

For example:
the target rate was 49 lbs/ac, and the initial scale 40:
the new scale setting is:

36

35.9

49

54.6

---------

40

×

=

NewScale

TargetRate

MeasuredRate

---------------------------------

OldScale

×

=

Barley (2 of 3)

7.5 inch

0

4

6

9

12

15

18

2

10 inch

0

3

5

6

9

11

13

1

Drive Type

2

0

5

10 15 20 25

30

3

Seed Rate Handle Setting

25

30

35

40

45

50

55

60

65

70

75

e

r

c

A

r

e

P

s

d

n

u

o

P

n

i

e

t

a

R

d

e

e

S

(

65

70

75

80

85

90

95

100

e

(based on 51 pounds/bushel)

104

114

123

133

142

152

154

156