4.2 SERVICE INFORMATION

If it becomes necessary to return this unit for repair, you must first contact

Aphex for a Return Authorization (RMA number), which will need to be

included with your shipment for proper identification. If available, repack

this unit in its original carton and packing material. Otherwise, pack the

equipment in a strong carton containing at least 2 inches of padding on

all sides. Be sure the unit cannot shift around inside the carton. Include a

letter explaining the symptoms and/or defect(s). Be sure to reference the

RMA number in your letter and mark the RMA number on the outside of

the carton. If you believe the problem should be covered under the terms of

the warranty, you must also include proof of purchase. Insure your shipment

and send it to:

APHEX

3500 N. San Fernando Blvd. Burbank, CA. 91505 USA

PH: 818.767.2929 FAX: 818.767.2641

INPUT

Type:

Impedance:

Unbalanced:

Nominal Level:

Maximum Level:

CMRR:

OUTPUT

Impedance:

Nominal Level

Maximum Level:

AUDIO

Frequency Response:

Dynamic Range:

THD:

IMD:

OPERATING LEVEL

Switch Setting:

+4dBu

Transformerless, active balanced
40KΩ
20KΩ
+4dBu
+24dBu
>40dB

110Ω
+4dBu

+24dBu Unloaded

+0.5dB 10Hz-38KHz
120dB
10Hz - 22kHz @ max output,
.0003%
10Hz - 22kHz 0 max output,
.0007%

6.0 SPECIFICATIONS

CONNECTOR PINOUT

1 CHASSIS GROUND

2 OUTPUT + (+4 LEVEL)

3 (unused)

4 OUTPUT - (+4 LEVEL)

5 COMMON

6 (unused)

7 (unused)

8 INPUT- (+4 LEVEL)

9 (unused)

10 INPUT+ (+4 LEVEL)

11 (unused)

12 +16VDC

13 POWER SUPPLY COMMON

14 -16VDC

15 (unused)

3500 N San Fernando Blvd. Burbank, CA 91505 USA

PH: 818.767.2929 FAX: 818.767.2641

www.APHEX.com

This product is protected under one or more of the following Aphex patents.

6,266,423