electrical connections

external connections

Two FastNet² connectors are provided at the rear of the unit. These
connectors allow connection to the rest of the system for the supply of power
and data.
The table below shows pin functions.

5

2

3

4

1

Front view of

male connector pins

Pin Number Signal

Pin Number Signal

Pin Number Signal

Pin Number Signal

1 12V

2 Busy

3 FastNet²-

4 FastNet²+

5 0V