Registers reading a register – Baseline Systems BFM Series Flow Meter User Manual

Page 4

Advertising
background image

REGISTERS

READING A REGISTER

4

• ‘M’ SERIES WATER METERS

M’ SERIES WATER METERS

5

READING A REGISTER

The Total Flow for a Water Meter register is calculated by adding the readings from the Totalizer

and the three fractional dials. The three fractional dials measure quantities smaller than the

totalizer reading and are continuously turning while calculating the flow.

Totalizer Reading: 0 0 x 100 = 0

Fractional Dial # 1: 7 7 x 10 = 70

Fractional Dial # 2: 5 5 x 1 = 5

Fractional Dial # 3: 7 7 x 0.1 = .7

NOTE: If a number is partially visible on the totalizer,

always default to the lower of the 2 numbers when

calculating flow. If a fractional dial is pointing between

numbers, always default to the lower of the 2 numbers.

CALCULATION:

Add Totalizer Reading and all Fractional Dial

Readings
0 + 70 + 5 + .7 = 75.7 U.S.G.

75.7 U.S. Gallons is the Current Total Flow

CALCULATING THE TOTAL FLOW FOR

THIS REGISTER

TOTALIZER READING: Rotates sequentially for

each 100 U.S.G. (U.S. Gallons) calculated

Number displayed is multiplied by 100 to reach

total U.S.G.
FRACTIONAL DIAL # 1: Each number (1-9) on

the dial is multiplied by 10 to reach U.S.G.

One complete revolution of this dial = 10 U.S.G.
FRACTIONAL DIAL # 2: Each number (1-9) on

the dial is multiplied by 1 to reach U.S.G.

One complete revolution of this dial = 1 U.S.G.
FRACTIONAL DIAL # 3: Each number (1-9) on

the dial is multiplied by 0.1 to reach U.S.G.

One complete revolution of this dial = 0.1 U.S.G.

Fractional

Dial #2

Fractional

Dial #3

Fractional

Dial #1

Totalizer

Reading

Fractional

Dial #2

Fractional

Dial #3

Fractional

Dial #1

Totalizer

Reading

GALLON

3/4” AND 1“

GALLON X 10

0.1

x 0.01 GALLON

x 0.1 GALLON
x 1.0 GALLON

GALLON

3/4” AND 1“

GALLON X 100

1.0

x 0.10 GALLON

x 1.0 GALLON

x 10 GALLON

REGISTER TOTALIZER
METER SIZE
VOLUME UNIT
PULSE OUTPUT (GALLONS/PULSE)
POINTER RESOLUTION - POINTER 1
POINTER RESOLUTION - POINTER 2
POINTER RESOLUTION - POINTER 3

REGISTER SPECIFICATIONS

REED SWITCH REGISTER

The Reed Switch Register is a dry contact or simple switch

closure for communicating with control and monitoring

equipment. Registers are interchangeable and easily

replaced with common tools. They are removable even when

the meter is operating. A leak indicator in the center of the

dial registers the lowest flow through the meter. Flows are

totalled in U.S. Gallons and each dial face indicates the

multiplication factor.

Magnetic coupling activates the reed switch

creating a pulsed output.

Dry contact uses very little electric power.

Calculates volume related functions such as

data recorders or simple counters.

Maximum contact current is 50mA and

maximum contact voltage is 48VDC.
Red Wire = Positive

Black Wire = Negative

PHOTO DIODE REGISTER

The Photo Diode Register has a photo coupler

sensor that provides pulse output for communicating

with control and monitoring equipment. Registers are

interchangeable and easily replaced with common tools.

They are removable even when the meter is operating.

Flows are totalled in U.S. Gallons and each dial face

indicates the multiplication factor.

A sensor combines an IR light source and a light

sensitive diode in one package. Signals are created

when the light beam created by the IR light is

interrupted by a rotating element.

Requires a constant supply of DC power.

Minimum contact current is 15mA to a maximum of 25mA

DC through a resistor and maximum voltage is 28VDC.
Yellow Wire = Positive (20-30mA through a resistor)

Transparent Wire = Output (open collector, max. load 2mA)

Bare Wire = Ground

TR

ANSP

ARENT :

OUTPUT (npn) - MA

X 2mA-25V

SHIELD:

GR

OUND MA

X.

VOL

TA

GE :

25

VDC

5 YELL

OW-MIN 15mA - MA

X 25mA DC

Black Wire

Red Wire

TR

ANSP

ARENT :

OUTPUT (npn) - MA

X 2mA-25V

SHIELD:

GR

OUND MA

X.

VOL

TA

GE :

25

VDC

5 YELL

OW-MIN 15mA - MA

X 25mA DC

Yellow

Wire

Transparent

Wire

Bare

Wire

RESISTOR VALUE - Ω
RESISTOR VALUE - W

180

0.25

220

0.25

330

0.25

470

0.5

1,000

1.0

RECOMMENDED RESISTOR VALUES

VOLTAGE ›

5

6

9

12

24

Note: Correct polarity

of the leads should be

checked carefully to

prevent damage of the

sensor. Register will not

function properly if the

register lid is not closed

during operation.

Reed

Switch

Only

NOTE: Always refer to the controller

manufacturer’s instructions for proper

installation and connection requirements.

Advertising