Attach the Saddle to the Pipe

2. Place the top half of the saddle with the

alignment slot inside the sensor housing on
the downstream side over the pipe so that
the mount fits into the drilled hole.

1. Make sure the o-ring seal is in place on the underside of the

saddle around the protruding sensor housing.

O-Ring

Mount

3. Attach the bottom half of the saddle to the top half on the

hinged side of the top half and close it around the pipe.

4. Push the larger end of the tapered wedge over the guides. Slide

it until the pieces of the saddle are clamped together. The
wedge should go on about halfway by hand. Finish setting the
wedge by tapping it a couple times with a rubber mallet.

5. Position the flow sensor insert so the arrow is pointing

downstream, and make sure that the key is aligned with the slot
inside the housing.

6. Push the insert straight in until the o-ring seals the opening.

7. Slide the retaining nut over the wire leads and turn the nut

clockwise by hand until it is tight.