Lightning and Surge Protection

 Lightning strikes are typically pulsed DC, but there is also an RF

component at about 2.2MHz. The first pulse averages 18kA.
Subsequent pulses are usually about half that. An average
lightning strike consists of 3 to 4 pulses.

 Antenna and equipment should be connected to a single point

earth ground. The best ground is an 8 ft or longer copper rod
driven into the soil. Alternate grounds are (in order of decreasing
effectiveness): building steel or rebar, cold water pipe, metal
building skin, or electrical system ground.

 With pole and tower grounding, use copper braid or strapping for

maximum energy dispersion.

 Ground all coax cable at the antenna and where the cable

leaves the tower or mounting pole. If the antenna mounting pole
is properly grounded, then the antenna and coax are grounded
via the antenna mounting bracket system. The coax should also
be grounded as low as possible where the cable leaves the tower
or mounting pole.

 Locate the lightning arrestor as close to the radio equipment as

possible.

 Ground the lightning arrestor using an AWG #8 wire and crimping

or soldering to the wire lug. The other side of the wire should be
connected to a solid earth ground. The connection point for the
ground wire should always be closer to the single point earth
ground than the radio equipment grounding location.

 Ground all of the components mentioned above together to a

common node (such as the antenna mast) if each is a short
distance away. This reduces the possibility of ground loops
through different earth grounds. However, if the distance from the
grounding point to the common node is greater than 20 ft, it may
be better to use separate earth grounds. Test the voltage at each
earth ground node to ensure ground potentials are equal.

 Waterproof all connections using a good waterproofing tape

such as a self-annealing rubber tape. Use an outer coating of
high quality vinyl electrical tape. Apply the tape in a spiral pattern
so the overlaps will act as shingles to shed water.

 Use DBR/Y or equivalent connectors for all wire connections.