Enclosure Electrical Installation, continued...

4. Connect enclosure power leads to facility power and then replace the cover on the wiring

compartment.

5. Connect conduit to the bottom of the enclosure.

6. Route a bare 6 AWG (4.11 mm) earth ground wire into the wiring area through the conduit

opening directly beneath the ground lug, in the bottom of the enclosure. Do not route the
ground wire through the same conduit as the incoming primary AC power!

7. Loosen the ground lug screw, insert the ground wire into the ground lug, and then tighten

the screw to secure the ground wire. Do not overtighten.

8. Power up the BaseStation controller and review the status LEDs on the BaseStation front

panel.

Follow Local Electrical Codes and Practices

Wi-Fi Modem with Antenna

(optional equipment)

biSensor Port

Labels

Zone Terminals

Two-wire

Connections

Wiring

Compartment

(Remove this

screw and lift

off the cover.)

Ground

Lug