Baseline Systems BL-5200R Powered biCoder User Manual

Page 2

Advertising
background image

BL-5200R Series Powered biCoder™

Installation Guide

1-866-294-5847

Rev 11.5.2012

www.baselinesystems.com

 

Follow Local Electrical Codes and Practices

Zone Terminals

Common
Terminals

Sensor Terminal

See “Burying the
biSensor” details in
the biSensor Install

DBR/Y or equivalent
moisture-resistant
connectors

Use wire nuts to test communication,
and then replace with Baseline approved
moisture-resistant connectors before
burying.

Sensor Terminal

biSensor Installation Instructions

1. Install the biSensor near the closest valve location. Follow the “Burying the biSensor” instructions

included with the biSensor.

2. Connect the red wire from the biSensor to the power wire or pilot wire of the valve and black wire from

the biSensor to the common wire of the solenoid using the provided DBG or equivalent waterproof
connectors. It is critical that polarity be maintained.

3. Connect the pilot wire from the valve to either the A1, A2, B1, or B2 terminals on the controller.

4. Press the biSensor update button and verify that the light above the terminal (A1, A2, B1,or B2) stays

on.

5. Assign the biSensor and test its operation according to the instructions in the controller’s user manual.