maintenance

Maintaining an air cleaner in proper condition is very important. Dirt 

induced through improperly installed, improperly serviced, or inadequate 

elements damages and wears out engines. Keep the element always 

clean.

1. Remove the cover.

2. Remove the air filter cover and element.

3. Wash the element in solvent and dry.

4. Oil the element and squeeze out excess oil. The element should be 

    wet but not dripping.

5. Insert the element into the air filter.

6. Install the covert.

Air Cleaner Service

A dirty air cleaner will restrict airflow to carburetor. To prevent carbure-

tor malfunction, service the air cleaner regularly. Service more frequently 

when operating the generator in extremely dirty areas.

NOTICE

Wash your hands with soap and water after handling used oil.

NOTICE

Please dispose of used motor oil in a manner that is compatible with 

the environment. We suggest you take it in a sealed container to your 

local service station for reclamation. Do not throw it in the trash or pour 

it on the ground.

WARNINg

Do not use gasoline or low flash point solvents for 

cleaning. They are flammable and explosive under 

certain conditions.