Cooper Instruments & Systems LXT 981 Torque Sensor User Manual

Page 5

Advertising
background image

CF 189

5

Rev. E; Dec. 12, 2011


EMI / EMC

Unit

Value

Tested

Standards

23 EN 61000-6-3: 2007

-

PASSED

24 EN 55011: 2009 + A1: 2010 class B

-

PASSED

25 EN 61000-6-2: 2005

-

PASSED

26 EN 61000-4-2 (ESD) : 2009

-

PASSED

27 EN 61000-4-3 (HF) : 2006 + A1: 2008 + A2: 2010

-

PASSED

28 EN 61000-4-4 (BURST): 2004 + A1: 2010

-

PASSED

29 EN 61000-4-5 (Surge): 2006

-

PASSED

30 EN 61000-4-6: 2009

-

PASSED

31 EN 61000-4-8: 2010

-

PASSED

32 EN 61000-4-11: 2004

-

PASSED

Load limits

4)

Unit

Value

33 Maximum measurable torque

%

110

34 Maximum torque, related to nominal torque

%

300

35 Ultimate torque

%

500

36 Maximum load of key stone (Application factor 1,5)

%

180

200

200

4) Based on the non-contact measurement principle the torque sensor is quite insensitive to bending

and shearing forces. Self-aligning couplings are recommended in case of dynamic loads.

4.0 VERSIONS AND ORDER OPTIONS

LXT 980 Accuracy 0.2%
LXT 981 Accuracy 0.1%

Option 1: Measurement range

5 0 Nm

1 0 0 Nm

2 5 0 Nm

5 0 0 Nm

1 0 0 0 Nm

2 0 0 0 Nm

Option 2: Angle sensor

0

without

angle

sensor

1

with angle sensor 360 P / Rev. (optical)

Option 3: Output signal

5)

A

analog

voltage

output

S

additional current output 4-20mA

P

additional

PWM

output

F

additional Frequency output 20-100kHz

Option 4: Shaft ends

6)

0

Standard round shaft ends with key stone

1

Square

shaft

ends

2

Hexagon

shaft

ends

Option 5: Protection class

0

IP50

1 IP64

(without

angle

sensor)

5) Only the analog voltage output is calibrated by default. All other output signals are adjusted according

to the analog voltage output.

6) The square and hexagon shaft ends are not in stock. They must be ordered separately first and their