CTEK Z4200U SkyRouter User Manual

Page 30

Advertising
background image

2 March 2014

26

Figure 18 - Relay Output Configuration

Relay Managed By Automation Control – When set to Yes the relay is controlled as an Output Pin with the Automation
Control application. When No the relay is solely under the control of the web screen and SMS interface.

Set Relay Output State – Used to set the current state of the relay driver circuit. The relay driver can be activated and
deactivated by changing this setting and pressing update.

Relay Initial Value - This pull down determines the initial state of the relay when the SkyRouter reboots or recovers from
a power failure. Choices are On, Off, or Last. Last will return the relay output to the state it was in when the power fail
occurred.

Relay Shut Off Timer – The relay driver circuit will revert to its default setting after the number of minutes or seconds
specified by this parameter. The two second setting is useful for resetting end point equipment.

Allow SMS Control of Relay – If Yes is checked the relay driver may be activated by sending an SMS with the command
“===R1” and deactivated by sending an SMS with the command of “===R0”. See TechNote TN009.

Allow Web Browser Control of Relay – If set to yes a button will appear on the Advertising screen to enable and disable
the relay driver circuit.

Text For Web Link To Relay – This text will appear on the advertising screen next to the relay activation button.

Advertising