13

T

roubleshooting

WARNING:

To reduce the risk of electric shock, turn

power OFF and disconnect plug from

electrical outlet before performing

maintenance or troubleshooting.

Vacuum cleaner won’t run

Possible causes

Remedies

1. Vacuum cleaner is not plugged in

1. Check electrical plug

2. Power button is not pressed down

2. Press power button down

Vacuum cleaner won’t pick up or low suction

Possible causes

Remedies

1. Tools, flex hose and/or telescoping

1. Remove each part and check for blockages

extension wand are blocked

2. Filters are dirty

2. Check and clean or replace pre-motor

and post-motor filters

3. Dust bag is full

3. Replace with new dust bag

4. Swivel hose not securely attached to suction opening

4. Make sure swivel hose is locked into

suction opening

5. Crack or hole in flex hose

5. Check hose and replace if needed

6. Air flow regulator or variable suction power

6. Change to closed or maximum setting

control is set to open or minimum setting

Visible dust escaping from vacuum

Possible causes

Remedies

1. Dust bag is full

1. Replace with new dust bag

2. Filters missing or installed incorrectly

2. Check pre-motor and post-motor filter for correct

installation

3. Filters are dirty

3. Check and clean or replace pre-motor and post-motor

filters

4. Flex hose is blocked

4. Remove hose and check for blockages

5. Swivel hose not securely attached to suction opening

5. Make sure swivel hose is locked into suction opening

6. Crack or hole in flex hose

6. Check hose and replace if needed

Other maintenance or service not included in the manual should be

performed by an authorized service representative.