SAVE THESE INSTRUCTIONS!

MP-4RD-1-_

- This product is ETL listed for indoor dry locations.
- This product can be installed to a 4" electrical box with
round plaster ring, or to an octagon electrical box.
- Minimum electrical box volume must be 6 cubic inches
(98 cubic centimeters).
- This product should be installed by a qualified electrician.

A

1: Turn the power to electrical box off.

2: Connect each low voltage wire coming from the remote
transformer to one power feed canopy wire with a wire nut.

Monorail 4" Round Single Power Feed Canopy

Installation Instructions for

Install the Canopy

1

904-MP-4RD-1-03

IMPORTANT INFORMATION

1718 W. Fullerton Ave

Chicago, IL 60614

Tel: 773-770-1195

Fax: 773-935-5613

www.edgelighting.com

[email protected]

2

NOTE:

Use the universal round crossbar (provided) if the electrical

box holes are not spaced 2-3/4" apart.

NOTE:

The low voltage wires should be present in the electrical

box. Refer to the instructions provided with the remote
transformer to install the transformer and the low voltage wires
before proceeding with the steps below.

2

B

4

3: Place all wires inside the electrical box.

4: Secure the power feed canopy to the electrical box by
tightening the two provided #8-32 screws with the 3/32
Allen wrench.

3/32 ALLEN
WRENCH

4

#8-32
SCREW

© 2009 Edge Lighting. All Rights Reserved.