SAVE THESE INSTRUCTIONS!

MP-2SQ-FE-_

- This product is ETL listed for indoor dry locations.

- Minimum electrical box volume must be 6 cubic inches
(98 cubic centimeter).
- This product should be installed by a qualified electrician.

- This product installs to Edge Lighting 2" electrical box only.

Installation Instructions for

Monorail 2" Square Feed-End Power

Canopy

1

904-MP-2SQ-FE-04

IMPORTANT INFORMATION

1718 W. Fullerton Ave

Chicago, IL 60614

Tel: 773-770-1195

Fax: 773-935-5613

www.edgelighting.com

[email protected]

A

1: For Single Ceiling Frame Stud, use the Monorail 2"
standoff to mount the Feed-End Power Canopy closest to the
ceiling. Refer to the chart below to determine the 2"
electrical box distance from the ceiling frame stud.

DRY WALL

THICKNESS

A

1/2"

0.29"

5/8"

0.42"

3/4"

0.54"

CEILING DRYWALL

JOIST

For New Construction

ELECTRICAL BOX

STUD

SINGLE CEILING
FRAME STUD

A

1.9"

B

2:

use the Monorail 4"

standoff to mount the Feed-End Power Canopy closest to the
ceiling. Refer to the chart below to determine the 2"
electrical box distance from the ceiling frame stud.

For Double Ceiling Frame Stud,

DRY WALL

THICKNESS

A

1/2"

0.95"

5/8"

1.08"

3/4"

1.22"

CEILING DRYWALL

JOIST

ELECTRICAL BOX

STUD

DOUBLE CEILING
FRAME STUD

A

4"