Install the remote transformer, Low voltage wire size chart – Edge Lighting 150W/12V Magnetic Remote Transformer User Manual

Page 2

Advertising
background image

LOW VOLTAGE WIRE SIZE CHART

TRANSFORMER
WATTAGE

WIRE SIZE
FOR 5 FT

WIRE SIZE
FOR 6-15 FT

WIRE SIZE
FOR 16-20 FT

WIRE SIZE
FOR 21-40 FT

150 WATT

#12 GA

#8 GA

#6 GA

#4 GA

2

Install the Remote Transformer

1: Use the transformer brackets to secure the transformer in
place (hardware not included).

2: Loosen and remove the two Phillips screws on the sides of
the transformer to remove the transformer cover.

A

COM

T1

T2

T3

T4

NOTE: In order to use small gauge wires from the transformer
to the electrical box, it is recommended to install the remote
transformers as near as possible to the electrical box. See "Low
Voltage Wire Size Chart" below.

TRANSFORMER COVER

TRANSFORMER
BRACKET

TRANSFORMER
BRACKET

PHILLIPS
SCREW

2

1

2

1

B

COM

T1

T2

T3

T4

CONDUIT

3: Install a conduit and power wires from the panel to the
transformer.

4: DO NOT connect the power wires to the panel at this time.

5: Connect the 120V black transformer wire to the hot power
with a wire nut.

6: Connect the 120V white transformer wire to the neutral
power with a wire nut.

HOT POWER
WIRE

NEUTRAL
POWER WIRE

3

6

5

Advertising