Caution – Carrier 58MEC User Manual

Page 10

Advertising
background image

10

;;

;;

BURNER FLAME

BURNER

MANIFOLD

A89020

Fig. 11 --

Burner Flame

RTV

PAM

A93081

Fig. 12 -- Gasket on Collector Box

Step 6 — Servicing Hot Surface Igniter

The igniter does NOT require annual inspection. Check igniter
resistance before removal.

1. Turn off gas and electrical supplies to furnace.
2. Remove main furnace door.
3. Disconnect igniter wire connection.
4.

Check igniter resistance. Igniter resistance is affect by tem-
perature. Only check resistance when the igniter is at room
temperature.

d. Using an ohm meter, check resistance across both ig-

niter leads in connector.

e. Cold reading should be between 40 ohms and 70 ohms.

5. Remove igniter assembly.

BURN HAZARD
Failure to follow this caution may result in personal injury.
Allow igniter to cool before removal. Normal operating
temperatures exceed 2000°F (1093°C).

CAUTION

!

a. Remove burner box cover.

b. Remove igniter wires from slot in manifold grommet.

(See Fig. 7.)

c. Using a 1/4 in. driver, remove the single screw securing

the igniter bracket to the burner box bracket (See Fig.
13.) and carefully withdraw the igniter and bracket as-
sembly through the front of the burner box without
striking the igniter on surrounding parts. Note that the
igniter bracket has a handle that extends to the front of
the burner box to aid in handling (See Fig. 13.).

d. Inspect igniter for signs of damage or failure.

UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit component
damage.
The igniter is fragile. DO NOT allow it to hit the side of the
burner box parts while removing or replacing it.

CAUTION

!

e. If replacement is required, replace igniter on igniter

bracket and then install assembly to burner box to avoid
damage to the igniter.

6. To replace igniter and bracket assembly, reverse items 5a

through 5d.

7. Reconnect igniter wire connection and insert the igniter

wires in the slot in the manifold grommet, dressing the ig-
niter wires to ensure there is no tension on the igniter itself.
(See Fig. 7.)

UNIT COMPONENT ELECTRICAL SHORT HAZARD
Failure to follow this caution may result in unit component

damage.
Igniter wires must be securely placed in slot in manifold

grommet or else they could become pinched or severed and

electrically shorted.

CAUTION

!

8. Reinstall burner box cover.
9. Turn on gas and electrical supplies to furnace.

10. Verify igniter operation by initiating furnace control board

self-test feature or by cycling thermostat.

11. Replace main furnace door.

58ME

C

Advertising