MOUNTING AND WIRING THE SAFETY SENSORS

• Slide a 1/4"-20x1/2" carriage bolt head into the slot on

each sensor. Use wing nuts to fasten sensors to
brackets, with lenses pointing toward each other
across the door. Be sure the lens is not obstructed by
a bracket extension. See Figure 5.

• Finger tighten the wing nuts.

Recommended Wire Routing

1. Using insulated staples, run the wires from both

sensors to the rail at the door header (see Figure 6).

2. Run the wires through wire clip at the top of the rails.

NOTE: If your access door is near the garage door,
you may choose to install the door control at this time
and run the door control wire along the rail with the
sensor wires. If you choose this option, follow
instructions 1-3 on page 20.

Invisible Light Beam
Protection Area

Safety Reversing
Sensor

Safety Reversing
Sensor

Bell Wire

Sensor Wire

Wire Clip

Rail

Figure 6

17

Carriage Bolt
1/4"-20x1/2"

Lens

Wing Nut
1/4"-20

Figure 5

Wing Nut
1/4"-20

Staples

Carriage Bolt

1/4"-20x1/2"

Wire Clip

HARDWARE SHOWN ACTUAL SIZE