Baumer ISI35 User Manual

Page 8

Advertising
background image

ISI34, ISI35

8

www.baumer.com

Model

Operating mode

Inputs

INP A

INP B

ISI34.010AX01

ISI34.011AX01

ISI34.013AX01

ISI35.010AX01

ISI35.011AX01

ISI35.013AX01

Timer

––

0

0 ... 0,7 V DC

Timer

––

10 ... 260 V AC/DC

0

4 ... 30 V DC

10 ... 260 V AC/DC

0

0 ... 0,7 V DC

0

4 ... 30 V DC

10 ... 260 V AC/DC

DC operating modes:

Timer:

INP A:

no function

INP B:

Timer-Enable-Input

AC operating modes:

Timer:

INP A:

Timer-Enable-Input AC/DC

INP B:

reset input AC/DC

Table 1

Time range

99999h 59 m/
99999.99 h

9999 h 59 m 59 s/
9999999.9 s

10 ... 260 V AC/DC

NPN

PNP

AC/DC

NPN

PNP

AC/DC

AC/DC

AC/DC

Options:

x = A: no backlight
x = B: with backlight

Main technical features:

Display:

LCD, 8 decades, height of the figures 8 mm

Display range:

0 ... 99999999 with leading zeros
suppression.

Accuracy:

< 100 ppm

Note:

For one ON/OFF-cycle the counter can lose
max. one impulse of the selected time
range

Overflow:

In case of a display range overflow, the
timer starts again from 0, but without
removing the leading zeros and activating
all decimal points.

Keys:

Electrical locking of the reset key

Housing:

Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021

Panel cut-out:

22,2

+0,3

x 45

+0,6

mm

Mounting depth:

approximately 48 mm

Weight:

approximately 50 g

Protection level:

IP65 on the front side

Connection:

Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1,5 mm

2

2 x 0,75 mm

2

AWG 26-14

EMC:

Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2

Device safety:
Design to:

EN61010 Part 1

Protection Class:

2

Application area:

Soiling Level 2

Power supply:

Non-replaceable lithium battery
(lifetime approximately. 8 years at 20°C)

Working temperature:

–10 ... +55 °C, relative humidity < 85%,
without condensation

Operating temperature:

–10 ... +60 °C

Storage temperature:

–20 .. +70°C

Altitude:

to 2000 m

Backlighting:

must be powered by an external elecrical
source (24 V ±20%, 50 mA)

Overview

1.10 Failure possibilities and causes

Impossible to use the keys:
- Key lock input activated

Counter does not count:
- Wrong or reversed wiring of the counting input
- Setting of an input signal not matching the pulse generator
- Polarity (NPN/PNP) reversed
- No ground connection between the pulse generator and the

counter

- Signal levels do not reach the switching threshold of the counter

If, despite all, your device still does not operate, contact your
local representative or call us directly for technical support.

When sending your device back, please attach a short descrip-
tion of the failure, of the programming and of the connection
diagram, in order to allow us to reproduce a possibly existing
defect and to repair your device as quickly as possible.