Baumer MXU cameras User Manual

Page 2

Advertising
background image

LED signals

LED

Signal

Meaning

LED

green

USB 3.0 connection

yellow

USB 2.0 connection

(settings possible, no image)

Installation

Installing the camera:

Connect the camera

to the USB

connection on your PC using an

appropriate cable.

If required, connect a trigger

and / or flash to the digital IOs.

open wire

Data Interface / Digital IOs

USB 3.0 Micro B

1 2 3 4 5

6 7 8 9 10

1

VBUS

6

MicB_SSTX-

2

D-

7

MicB_SSTX+

3

D+

8

GND_DRAIN

4

ID

9

MicB_SSRX-

5

GND

10

MicB_SSRX+

Caution

The General Purpose IOs (GPIOs) are not potential-free and do not have

an overrun cut-off. Incorrect wiring (overvoltage, undervoltage or voltage

reversal) can lead to defects within the electronics system.

GPIO Power V

CC

:

3.3 V DC

IOUT:

max. 8 mA

The GPIOs are configured as an input through the default camera

settings. They must be connected to GPIO_GND if not used or not

configured as an output.

Digital IOs

1

8

1

Shielding

5

GPIO1

2

IN1

6

GPIO2

3

IO GND

7

IO Power VCC

4

OUT 1

8

GPIO_GND

Installation example

1 - PCI USB board

2 - USB cable

3 - Cable for trigger and flash

Troubleshooting

1. Check camera operation using the LED signals.

→ If LED is yellow:

• Camera is connected to USB 2.0 (settings possible, no image).

→ If LED is green:

• Check if camera is being used by another application.

• Otherwise reconnect camera / restart software.

2. Check connection using Windows Device Manager:

→ If device is not listed:

• Check the host controller power supply.

• Check USB 3.0 cable and connection.

→ If device is regularly not listed

• Check USB 3.0 driver installation.

Heat Transmission

Caution

Heat can damage the camera. Heat must be dissipated adequately to

ensure that the temperatures do not exceed

the values in the table below.

As there numerous options for installation, Baumer does not specify a

specific method for proper heat dissipation.

For applications with enough free space, the use of the Baumer heat sink

(No. 11118288) is recommended.

Caution

Device heats up during opera ion.

Skin irritation possible.

Do not touch the camera and/or heat sink during operation.

Measurement Point

Maximum Temperature

T

80°C (176°F)

General Description

1

2

4

5

3

No.

Description

No.

Description

1

Print sensor

4

Digital IOs

2

Flexprint cable

5

USB 3.0 port

3

System print

T