Error messages, Technical information – Chauvet 300E User Manual

Page 30

Advertising
background image

Technical Information


-26-

Legend 300E Spot User Manual Rev. 01g

Error Messages

Message

Cause(s)

Action(s)

Lamp Startup Fail

The lamp has not started after being struck

· Check lamp
· Check lamp socket and wiring

· Check ballast and igniter

Temperature Sense
Error

No communication with temperature
sensor

· Check sensor wiring
· Check sensor integrity

· Check control board

Lamp too Hot Low
Power

Ambient temperature higher than 105º C;
lamp in low power for safety

· Check fans

· Check fan wiring
· Clean vents

Lamp Too Hot Power Off Ambient temperature higher than 110º C;

lamp off for safety

· Check fans

· Check fan wiring
· Clean vents

Maintenance Fixture

Fixture Maintenance timer expired

· Proceed with maintenance and reset timer

Lamp On Over 700 Hour Lamp change is overdue

· Change lamp

Memory Initial Fail

Memory chip error

· Change main board

CPU-B Error
CPU-C Error
CPU-D Error

No communication with auxiliary CPU

· Check sensors wiring and position
· Check stepper motor, belt, and driver board

· Check control boards

Pan Reset Error
Pan Encode Error
Tilt Reset Error
Tilt Encode Error

Moving head failed going to home position
after power up or fixture reset

· Check moving head’s free movement
· Check sensors’ wiring and position
· Check stepper motor, belt, and driver board

· Check the corresponding control board
· Check main control board

Shutter Reset Fail
Dimmer Reset Fail
Color Reset Fail
Cyan Reset Fail
Magenta Reset Fail
Yellow Reset Fail
Gobo Reset Fail
R-Gobo Reset Fail
Effect Reset Fail
R-Effect Reset Fail
Frost Reset Fail

Indicated moving part failed going to home
position after power up or fixture reset

· Check part’s free movement and integrity
· Check sensors’ wiring and position

· Check stepper motor, belt, and driver board
· Check the corresponding control board

· Check main control board