Ex-Application

A FlexTop 2221 with type number 2221 0002 is approved for Ex ia IIC
T5/T6 and ATEX II 1G.

The installation of FlexTop 2221 must be done in accordance with
prevailing guidelines for zones 0 or 1.

An Ex ia certifi ed zener or isolation barrier with the entity parameters
V

max

< 30 V

DC

; I

max

< 0.1 A; P

max

< 0.75 W must be used.

The FlexTop 2221 entity parameters (terminals + to -) are:
L

i

< 15 µH; C

i

< 5 nF.

Sensor circuit parameters (terminals 3 to 6):
V

DC

< 6.6 V; I

DC

< 17 mA; P

out

< 30m W; L

a

< 99 mH; C

a

< 3µF.

The FlexTop 2221 must be connected in the 4...20 mA loop circuit only.

FlexTop 2221 must be mounted in a housing, e.g. ø80mm stainless
steel housing (type number 81 43-110), DIN-B housing (type number
81 43-120) or the like.
Refer to page 3 for futher technical data.

WARNING

This product contains no replaceable parts.
In case of malfunction the product must be shipped to Baumer for
repair.

Ex-Connection Diagram/Control Drawing

4...20 mA

24 V

dc

5

6

2

1

3

4

RTD

Zone

0/1 Safe

area

230

V

ac

1 2

-

+

+ -

3 4

-

+

FlexTop 2221

Barrier

FlexView

Power Supply

Ex nA II T5, ATEX II 3G - Installation

A FlexTop 2221-0003 is Ex nA II T5, ATEX II 3G approved for ap-
plication in hasardous areas in accordance with the current EU-direc-
tives. The product must be mounted in a suitable enclosures fulfi lling
relevant requirement in EN 60 079-0 among these minimum IP54
ingress protection.

Ex-data

Supply range

12...30 VDC, Max. 0,1A

Temperature class T1...T5.