Product Specification

VisiLine– Innovative functionality

Flexible assembly

RGB and YUV interpolation algorithms on board

Bandwidth up to 1000 Mbit/sec for fast multi-camera operation

Flexible system architecture due to cable length up to 100 m

Baumer driver for reliable image transfer

PoE (Power over Ethernet)

Camera Type

Sensor

Size

Resolution

Full Frames

[max. fps]

CCD Sensor (monochrome / color)

VLG-02M / VLG-02C

1/4"

656 x 490

160

VLG-12M / VLG-12C

1/3"

1288 x 960

42

VLG-20M / VLG-20C

1/1.8"

1624 x 1228

27

CMOS Sensor (monochrome / color)

VLG-22M / VLG-22C

2/3"

2044 x 1084

55

VLG-40M / VLG-40C

1"

2044 x 2044

29

System Requirements

Single-camera system

Multi-camera system

Minimum

Recommended

Minimum

Recommended

CPU

Intel

®

Pentium

®

4

or comparable

processor

Intel

®

Core™ Duo comparable processor

Clock

2.5 GHz

> 2.5 GHz

2.5 GHz

3 GHz

RAM

1024 MB

2048 MB

2048 MB

> 2048 MB

Operating

system

(OS)

Microsoft

®

Windows

®

XP incl. Service Pack 2 or higher

Microsoft

®

Windows

®

XP x64 incl. Service Pack 2 or higher

Microsoft

®

Windows Vista™ 32 / 64 bit systems

Microsoft

®

Windows 7 32 / 64 bit systems

Linux

®

32 / 64 bit systems from Kernel 2.6.xx

Graphic

recommended resolution 1280 x 1024, color depth at least 16 bit

Ethernet

Gigabit Ethernet compliant NIC (recommended Intel

®

chipset)

Framework

(optional)

Windows

®

OS: NET™ Framework 2 0 or higher

Linux

®

OS: Mono 1 2.4 or higher

Dimensions

temperature

measurement point

Front View

Side View

Back View

Bottom View

C Mount

2 M3 depth 3

2 M3 depth 3

2 M2 depth 3

Pixel 0,0

2 M3 depth 3

4 M3 depth 3

8 7

8 7

15 6

20

9,3

3,5

26

14 5

48 3

9 6

33

33

26

12

3,5

8,6

26

26

30

ø

Safety

Further Information

For further information on our products visit www.baumer.com

For technical issues, please contact our technical support:

[email protected] Phone +49 (0)3528 4386-0 Fax +49 (0)3528 4386-86

© Baumer Optronic GmbH Badstrasse 30 DE-01454 Radeberg, Germany

Technical data has been fully checked, but accuracy of printed matter not guaranteed.

Subject to change without notice. Printed in

Germany

02/14.

v1.2

11107528

FCC – Class B device

This equipment has been tested and found to comply with

the limits for a Class B digital device, pursuant to part 15

of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference in a

residential environment. This equipment generates, uses,

and can radiate radio frequency energy and, if not installed

and used in accordance with the instructios, may cause

harmful interference to radio communications. However,

there is no guarantee that interference will not occure in a

particular installation. If this equipment does cause harmful

interference to radio or television reception, which can be

determined by turning the equipment off an on, the user

is encouraged to try to correct the interference by one or

more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and the

receiver.

Connect the equipment into an outlet on a circuit different

from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician

for help.

Conformity:

CE, FCC Part 15 Class B, RoHS

Notice

Further technical details are

available in the respective

data sheet.

Safety Precautions

Notice

See User s Guide for the com-

plete safety instructions!

Protect the sensor from dirt and

moisture.

Avoid camera contamination by

foreign objects.

Environmental Requirements

Storage temp.

-10°C ... +70°C

Operating temp.

see Heat Trans-

mission

Humidity

10 % ... 90 %

Non-condensing

Quick Start Guide

VisiLine Gigabit Ethernet cameras

Latest software version and technical

documentation are available at:

www.baumer.com/vision/login