Baumer GXP6W User Manual

Page 11

Advertising
background image

Manual_GXP6W_EN.doc

11/14

Baumer IVO GmbH & Co. KG

04.05.11

Villingen-Schwenningen,

Germany

8.3 Settings of user adresses

Last user

User X

ON

ON

1

1



8.4 EMV-cable

gland

The shielding of the contact cables must be done at the PG cable glands (PG7 and PG9).

The following are used:

1 x PG7 for voltage supply

2 x PG9 for data lines

Mounting:

Strip the oversheath of the cable to ca. 35 mm (Picture 1), use connector sleeves

with litz cables. Push cap nut and seal insert onto cable sheath, shorten aluminum

foil,

if available, put braided screen over seal insert and shorten to 15 mm (Picture 2),

slide seal with cable into EMC PG cable gland and fix with cap nut.

Picture 1

Picture 2

The following cable cross-sections are admitted for the PGs:

PG7: Cable cross-section - 4,0mm - 6,0mm
PG9: 2-piece seal insert:

- 5,0mm - 7,0mm

- 7,0mm - 10mm


ca. 5

15

Cable

Wire

Screen

20

Cable

Wire

Screen

Seal

Alu film