8.3 Settings of user adresses
Last user
User X
ON
ON
1
1
8.4 EMV-cable
gland
The shielding of the contact cables must be done at the PG cable glands (PG7 and PG9).
The following are used:
1 x PG7 for voltage supply
2 x PG9 for data lines
Mounting:
Strip the oversheath of the cable to ca. 35 mm (Picture 1), use connector sleeves
with litz cables. Push cap nut and seal insert onto cable sheath, shorten aluminum
foil,
if available, put braided screen over seal insert and shorten to 15 mm (Picture 2),
slide seal with cable into EMC PG cable gland and fix with cap nut.
Picture 1
Picture 2
The following cable cross-sections are admitted for the PGs:
PG7: Cable cross-section - 4,0mm - 6,0mm
PG9: 2-piece seal insert:
- 5,0mm - 7,0mm
- 7,0mm - 10mm
ca. 5
15
Cable
Wire
Screen
20
Cable
Wire
Screen
Seal
Alu film