This instrument is built and tested according to the current EU-
directives and packed in a technically safe condition. In order to main-
tain this condition and to ensure safe operation, the user must follow the
hints and warnings given in this instruction.

During the installation the valid national rules have to be observed. Ig-
noring the warnings may lead to severe personal injury or substantial
damage to property.

The product must be operated by trained staff. Correct and safe opera-
tion of this equipment is dependent on proper transport, storage, instal-
lation and operation.

All electrical wiring must conform to local standards. In order to prevent
stray electrical radiation, we recommend twisted and shielded input
cables, as also to keep power supply cables separated from the input
cables. The connection must be made according to the connection dia-
grams.

Before switching on or off the power supply take care that other equip-
ment is not effected. Ensure that the supply voltage and the conditions
in the environment comply with the specification of the device.

Description

The DFON is powered by the 4…20 mA loop and need no additional power supply. When mounted on new instrument series like
the CombiPress™ PFMx it is via the internal UnitCom ribbon cable supplied with power and a digital signal, instead of integrated in
the 4…20 mA loop. In instruments with UnitCom both the transmitter and display can be programmed at the same time alternative-
ly separate programming of each device can be selected.

The DFON has an unique background colour setting. Three colours are available – White / Red / Green and further the red and
green colour can be set as flashing in warning mode.

The DFON has two integrated galvanic separated relays. The instrument can be delivered with or without activated relays. If sup-
plied without activated relays, those can be activated by purchasing a license code from Baumer. By entering the code to the in-
strument via the FlexProgrammer the relays are enabled.

The DFON can be programmed by the touch screen on the display or by the FlexProgrammer 9701 Baumer programming unit with
the Baumer FlexProgram installed on a PC.

(Free download from www.baumer.com > Services > Downloads > Software < Flex…)

The DFON can be delivered as a loose display or as an integrated part of an instrument e.g. PFMx, TFRx.

Alternatively it can be delivered as a loop-powered local display for any instrument in a SS case for wall mounting, panel mounting
or tube mounting.

Operators instructions
CombiView™, type DFON

DFON graphical displays are used as separate units, but also used
in complete instruments,

e.g. CombiPress™, CombiTemp™