Read / write limit positions „g“ (67h), N 153, How to calculate the scaling factor – Baumer N 153 User Manual

Page 19

Advertising
background image

N 153

www.baumer.com

19

4.3.4. Read / write spindle pitc (scaling factor) „c“ (63h)

This command is utilized to read or write the scaling factor relating to the spindle pitch within the range from
0,0000001...9,9999999. The decimal point is not transmitted.
Resolution per turn is 1440 steps. A scaling factor of 1.000000 will increase respectively decrease the indicated
value by 14.4 mm.

How to calculate the scaling factor:

Resolution per turn: 14.40 mm (corresponding to length with scaling factor 1.0000000)

Spindle pitch:

4.00 mm

Spindle pitch 4.00
scaling = ───────────────── = ───── = 0.2777777

resolution per revolution 14.40

Example 1: Read scaling (scaling factor = 1.000000)

SOH

Adr

Cmd

EOT

CRC

Transmission

01h

20h

63h

04h

4Ah

SOH

Adr

Cmd

Scaling factor = 1.0000000

EOT

CRC

Response

01h

20h

63h

31h

30h

30h

30h

30h

30h

30h

30h

04h

4B


Example 2: Write scaling (scaling factor = 0.2777777)

SOH

Adr

Cmd

Scaling factor = 0.2777777

EOT

CRC

Transmission

01h

20h

63h

30h

32h

37h

37h

37h

37h

37h

37h

04h

30h

SOH

Adr

Cmd

Scaling factor = 0.2777777

EOT

CRC

Response

01h

20h

63h

30h

32h

37h

37h

37h

37h

37h

37h

04h

30h

4.3.5. Read / write limit positions „g“ (67h)

This command is utilized to read or write the MIN and MAX limit positions within the range from -999.99 to
9999.99. The decimal point is not transmitted.

Example 1: Read limit positions (MIN = 15.00; MAX = 850.25)

SOH Adr Cmd EOT CRC

Transmission

01h 20h 67h 04h 42h

SOH Adr Cmd

MIN limit position = 0015.00

MAX limit position = 0850.25

EOT CRC

Response

01h 20h 67h 30h 30h 31h 35h 30h 30h 30h 38h 35h 30h 32h 35h 04h 1Fh


Example 2: Write limit positions (MIN = -33.22; MAX = 1234.56)

SOH Adr Cmd

MIN limit position = -033.22

MAX limit position = 1234.56

EOT CRC

Transmission

01h 20h 67h 2Dh 30h 33h 33h 32h 32h 31h 32h 33h 34h 35h 36h 04h 92h

SOH Adr Cmd

MIN limit position = -033.22

MAX limit position = 1234.56

EOT CRC

Response

01h 20h 67h 2Dh 30h 33h 33h 32h 32h 31h 32h 33h 34h 35h 36h 04h 92h

4.3.6. Read / write motor speed switching points „h“ (68h)

This command is utilized to read or write the motor speed switching points. Prior to reaching the target the mo-
tor speed can be slowed down for high-precise target positioning. Furthermore it is possible to set the motor
switch-off point at a designated value relating to the target. The following two parameters are defined:

Precision speed: point where SPA changes from high speed to precision speed.
Switch off point: Position where motor is stopped by SPA .

The individual switching points are indicated in relation to the target.

Example 1: Read parameter (precision speed = 0.70; switchoff point = 0.02)

SOH Adr Cmd EOT CRC

Transmission

01h 20h 68h 04h 5Ch

SOH Adr Cmd

reserved

Precision speed =0.70

Switchoff point =0.02

EOT CRC

Response

01h 20h 68h 30h 30h 30h 30h 30h 30h 37h 30h 30h 30h 30h 32h 04h 66h