Important safety instructions, Electric wall oven installation instructions, Carpentry – FRIGIDAIRE FEB24S5AS User Manual

Page 3: Electrical requirements

Advertising
background image

3

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

Important Notes to the Installer

1. Read all instructions contained in these installation

instructions before installing the wall oven.

2. Remove all packing material from the oven

compartments before connecting the electrical supply
to the wall oven.

3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Oven door may be removed to facilitate installation.
6. THESE OVENS ARE NOT APPROVED FOR

STACKABLE OR SIDE-BY-SIDE INSTALLATION.

Important Note to the Consumer

Keep these instructions with your Owner's Guide for
future reference.

IMPORTANT SAFETY INSTRUCTIONS

Be sure your wall oven is installed and grounded

properly by a qualified installer or service
technician.

This wall oven must be electrically grounded in

accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA
No.70- latest edition in United States, or with CSA
Standard C22.1, Canadian Electrical Code, Part 1,
in Canada.

Stepping, leaning or sitting on the

door of this wall oven can result in serious injuries
and can also cause damage to the wall oven.

Never use your wall oven for warming or heating

the room. Prolonged use of the wall oven without
adequate ventilation can be dangerous.

The electrical power to the oven must

be shut off while line connections are being made.
Failure to do so could result in serious injury or
death.

1. Carpentry

Refer to figure 1 or 2 for the dimensions applicable to
your appliance, and the space necessary to receive the
oven. The oven support surface may be solid plywood or
similar material, however the surface must be level from
side to side and front to rear.

2. Electrical Requirements

This appliance must be supplied with the proper voltage
and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker
or fuse. To know the circuit breaker or fuse required
by your model, see the serial plate to find the wattage
consumption and refer to table A to get the circuit
breaker or fuse amperage.

Observe all governing codes and local ordinances

1. A 3-wire or 4-wire single phase 120/240 or 120/208

Volt, 60 Hz AC only electrical supply is required on a

separate circuit fused on both sides of the line (red

and black wires). A time-delay fuse or circuit breaker is

recommended. DO NOT fuse neutral (white wire). Only

certain cooktop models may be installed over certain

built-in electric oven models. Approved cooktops and

built-in ovens are listed by the MFG ID number (see the

insert sheet included in the literature package).

NOTE: Wire sizes and connections must conform with

the fuse size and rating of the appliance in accordance

with the American National Electrical Code ANSI/NFPA

No. 70-latest edition, or with Canadian CSA Standard

C22.1, Canadian Electrical Code, Part 1, and local codes

and ordinances.

An extension cord should not be used

with this appliance. Such use may result in a fire,

electrical shock, or other personal injury. If you need

a longer power cord you can purchase a 10' (3 m) power

cord kit #903056-9010 by calling the Service Center.
2. These appliances should be connected to the fused

disconnect (or circuit breaker) box through flexible

armored or nonmetallic sheathed cable. The flexible

armored cable extending from the appliance should

be connected directly to the junction box. The

junction box should be located as shown in Figure

1 or Figure 2 and with as much slack as possible

remaining in the cable between the box and the

appliance, so it can be moved if servicing is ever

necessary.

3. A suitable strain relief must be provided to attach

the flexible armored cable to the junction box.

Table A

Appliance

Rating Watts

240V

Protection

Circuit

Recommended

Appliance

Rating Watts

208V

Protection

Circuit

Recommended

Less than 4800W

20A

Less than 4100W

20A

4800W - 7200W

30A

4100W - 6200W

30A

7200W - 9600W

40A

6200W - 8300W

40A

9600W and +

50A

8300W and +

50A

Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until appliance

is permanently grounded.

• Disconnect power to the junction box before making

the electrical connection.

• This appliance must be connected to a grounded,

metallic, permanent wiring system, or a grounding
connector should be connected to the grounding
terminal or wire lead on the appliance.

• Do not use a gas supply line for grounding the appliance.

Failure to do any of the above could result in a fire,

personal injury or electrical shock.