Operation, Installation, Portable air compressors – Campbell Hausfeld IN628602AV User Manual

Page 4: Cont.)

Advertising
background image

Never connect

green (or green and

yellow) wire to a live terminal.

Check with a qualified electrician
or serviceman when the grounding
instructions are not completely
understood, or when in doubt as
to whether the product is properly
grounded. Do not modify the plug
provided; if it does not fit the outlet,
have the proper outlet installed by a
qualified technician.
This product is for use on a nominal
120V circuit and has a grounding plug
similar to the plug illustrated in Figure
2. Only connect the product to an
outlet having the same configuration
as the plug. Do not use an adapter with
this product.
ExTENSION CORDS

To avoid loss of

power and

overheating, it is better to use
additional air hose instead of extension
cords to reach work area.

Use only a 3-wire extension cord that
has a 3-blade grounding plug, and
a 3-slot receptacle that accepts the
plug on the product. Make sure your
extension cord is not damaged. When
using an extension cord, be sure to use
one heavy enough to carry the current
your product draws. An undersized
cord results in a drop in line voltage
and loss of power and overheating.
[The table shows the correct size to
use depending on cord length and
nameplate ampere rating. When in
doubt, use the next heavier gauge.
The smaller the gauge number, the
heavier the cord.]

Extension cords for

120V/10 Amp Unit

Length of
Cord (ft)

25

50

100

Gauge of
Cord

16

14

10

Operation

• Pressure Switch - ON/OFF Switch

(Figure 3) - In the ON position, the
compressor shuts off automatically
when tank pressure reaches the
maximum preset pressure. In the

4

Portable Air Compressors

OFF position, the compressor will
not operate. This switch should be in
the OFF position when connecting
or disconnecting the power cord
from the electrical outlet or when
changing air tools.

Regulator - The regulator controls

the amount of air pressure released
at the hose outlet.

ASME Safety Valve - This valve

automatically releases air if the
tank pressure exceeds the preset
maximum.

Exhaust Tube - This tube carries

compressed air from the pump to
the check valve. This tube becomes
very hot during use. To avoid the
risk of severe burns, never touch
the exhaust tube.

Check Valve - A one-way valve

that allows air to enter the tank, but
prevents air in the tank from flowing
back into the compressor pump.

Handle - Designed to move the

compressor.

Drain Valve - This valve is located on

the bottom of the tank. Use this valve

www.chpower.com

Installation

(Cont.)

AUT

O

OFF

Figure 3 - ON/OFF Switch

HM7500

HM7510

Outlet pressure
gauge

Air outlet /
coupler

Regulator

Tank pressure
gauge

ASME Safety
valve

NOTE: Drain Valve on bottom of units (not shown).

Pressure
switch

Outlet
pressure
gauge

Air outlet /
coupler

Regulator

ASME Safety valve

Pressure switch

Tank pressure gauge