30" gas slide-in range installation instructions, Provide an adequate gas supply, Seal the openings – FRIGIDAIRE FGGS3065PF User Manual

Page 7: Connect the range to the gas supply

Advertising
background image

7

30" GAS SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with Sealed Top Burners)

2.

Provide an adequate Gas Supply

When shipped from the factory, this unit is designed

to operate on 4" (10,16 cm) water column (1.0 kPa)

Natural gas manifold pressure. A convertible pressure

regulator is connected to the range manifold and

MUST be connected in series with the gas supply line.

If LP/Propane conversion kit has been used, follow

instructions provided with the kit for converting the

pressure regulator to LP/Propane use.
Care must be taken during installation of range not to

obstruct the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure

to the regulator should be no more than 14" (35,56

cm) of water column pressure (3,5 kPa). The inlet

pressure to the regulator must be at least 1" (0,25 kPa)

greater than the regulator manifold pressure setting.

Examples: If regulator is set for natural gas 4" (10,16

cm) manifold pressure, inlet pressure must be at least

5" (12,7 cm); if regulator has been converted for LP/

Propane gas 10" (25,4 cm) manifold pressure, inlet

pressure must be at least 11" (27,9 cm).
Leak testing of the appliance shall be conducted

according to the instructions in step 4.
The gas supply line should be ½" or ¾" I.D. (Interior

Diameter)

3.

Seal the openings

Seal any openings in the wall behind the range and

in the floor under the range after gas supply line is

installed.

4.

Connect the range to the gas

supply

Important: Remove all packing material and literature

from range before connecting gas and electrical

supply.

To prevent leaks, put pipe joint sealant on all external

pipe threads.

Your regulator is in location as shown in figure 3.

Do not allow regulator to rotate on

pipe when tightening fittings.

Connection to Pressure Regulator

The regulator is already installed on the appliance.

Do not make the connection too tight.

The regulator is die cast. Overtightening may crack the

regulator resulting in a gas leak and possible fire or

explosion.

Assemble the flexible connector from the gas supply

pipe to the pressure regulator in the following order:

1. manual shutoff valve (not included)

2. 1/2" nipple (not included)

3. 1/2" flare union adapter (not included)

4. flexible connector (not included)

5. 1/2" flare union adapter (not included)

6. 1/2" nipple (not included)

7. pressure regulator (included)
Use pipe-joint compound made for use with Natural

and LP/Propane gas to seal all gas connections. If

flexible connectors are used, be certain connectors are

not kinked.
The supply line must be equipped with an approved

manual shutoff valve. This valve should be located

in the same room as the range and should be in a

location that allows ease of opening and closing.

Shutoff Valve -

Open position

to appliance

to gas suppl

y line

Figure 4

• If you are using a through the floor gas entry, remove

the line protector shield from the bottom of the unit to

allow access for the pipe line (figure 3).

• We recommend to install a pipe elbow right out of the

floor or wall towards the center of the unit to ease the

installation.

To remove the line protector, remove the 3

screws.

Figure 3

Gas pressure regulator location

Do not block

access to the

shutoff valve.
The valve is

for turning on

or shutting

off gas to the

appliance.

All connections must be wrench-tightened

Flare

Union

Flare

Union

GAS FLOW

Manual

Shutoff

Valve

Pressure

Regulator

On

Off

Flexible

Connector

Access

Cap

Nipple

Nipple

Advertising