Installation instructions, 8 ventilation system – FRIGIDAIRE FGBM205KW User Manual

Page 4

Advertising
background image

E

INSTALLATION INSTRUCTIONS

4

8 VENTILATION SYSTEM

(PREPARING OVEN FOR INSTALLATION)

This Over the Range Microwave Oven is designed for
adaptation to three types of hood ventilation systems. Select
the type required for your installation.

RECIRCULATING — non-vented, ductless. Follow installation
procedure (A). Recirculating requires the use of the
Charcoal Filters, which have already been installed in
the oven.

HORIZONTAL EXHAUST — outside ventilation. Follow
installation procedure (B).

VERTICAL EXHAUST — outside ventilation. Follow
installation procedure (C).

(A) RECIRCULATING:

NON-VENTED, DUCTLESS OPERATION

The unit is shipped assembled for recirculating.

NOTE:

1. The Exhaust Damper Assembly is not required for

recirculating exhaust.

2. The Charcoal Filters should be replaced every 6 to 12

months, depending on use.

(B) HORIZONTAL EXHAUST:

OUTSIDE VENTILATION

1. Remove 3 screws from back edge and 5 screws from the

top of Fan Cover Bracket. Save 3 screws to use them to
attach Exhaust Damper Assembly to the wall later and
discard remaining 5. Remove Fan Cover Bracket by
sliding it in the opposite direction of the arrow on the Fan
Cover Bracket, as shown in Figure 7.

2. Lift Hood Fan Unit carefully and slip wires out of cavity.

See Figure 8. CAUTION: Do not pull or stretch Hood Fan
Wire.

3. Rotate the Hood Fan Unit 180˚ so that the Fan Blade

Openings are facing the back of the oven. See Figure 9A on
page 5.

4. Replace Hood Fan Wire from (A) to (B). See Figure 9B

on page 5. Replace Hood Fan Unit into the oven. Be
careful not to pinch the Hood Fan Wire and the Hood
Fan Unit.
See Figure 9C on page 5.

5. Put the wire back into cavity. See Figure 10A on page 5.

6. Assemble the Exhaust Damper Assembly to the Fan

Cover Bracket by sliding it into the slits in the same
direction as the arrow. Use 1 Tapping Screw 4 x 8 mm
from the INSTALLATION HARDWARE and tighten into
place. See Figure 10B on page 5.

7. This assembly will be mounted to the Outside Rear

Exhaust cutout in future instructions. See WALL
TEMPLATE for further procedures.

Oven Light Cover

Hood Louver

Upper Tab

Figure 6A

Figure 6B