30" ELECTRIC DROP-IN RANGE INSTALLATION INSTRUCTIONS

30”

(76.2 cm)

26½”

(67.3 cm)

27½”

(69.9 cm)

31 / ”

(79.5 cm)

16

21¾”

(55.25 cm)

5

Door open

(see note 4)

1 1/8"

(2.86 cm)

FRONT

OF

CABINET

B

Ref.

22 7/8"*

(58.1 cm) min.

23 1/4"*

(59.05 cm) max.

* For cutouts below 22 7/8", appliance

will slightly show out of the cabinet.

NOTES:

1. Do not pinch the power supply cord

between the range and the wall.

2. Do not seal the range to the side

cabinets.

3. 24" (61 cm) minimum clearance

between the cooktop and the bottom

of the cabinet when the bottom of

wood or metal cabinet is protected

by not less than 1/4" (0.64 cm)

flame retardant millboard covered

with not less than No. 28 MSG sheet

metal, 0.015" (0.4 mm) stainless

steel, 0.024" (0.6 mm) aluminum,

or 0.020" (0.5 mm)

copper.

30" (76.2 cm)

minimum clearance

when the cabinet is

unprotected.

4. Allow at least 20" (50.1

cm) clearance for door

depth when it is open.

A. Cutout Width

(Countertop and

cabinet)

B. Cutout Depth

(According to front of

cabinet)

C. Height of

Cutout

30 ±

1/16

"

(76.2 ± 0.15 cm)

21 3/4" (55.2 cm) min

22 1/8" (56.2 cm) max

29" (73.7 cm)

IMPORTANT:

Cabinet and countertop

width should match the cutout width.

A

A

Advertising