Lp/propane gas conversion – FRIGIDAIRE FGDS3065KW User Manual

Page 9

Advertising
background image

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with an Electric Oven and a Gas Cooktop)

9

Assemble the flexible connector from the gas supply
pipe to the pressure regulator in the following order:
1. manual shutoff valve (not supplied)
2. 1/2" nipple (not supplied)
3. 1/2" flare union adapter (not supplied)
4. flexible connector (not supplied)
5. 1/2" flare union adapter (not supplied)
6. 1/2" nipple (not supplied)
7. pressure regulator (supplied)
The gas supply line to the shutoff valve should be

1/2"(1,27 cm) or 3/4"(1.9 cm) solid pipe.
The user must know the location of the main shutoff
valve and have easy access to it.
When using flexible gas conduit on the range, allow

sufficient slack to pull the range outside the cutout for

cleaning or servicing.
NOTE: Do not allow the flexible conduit to get pinched

between the wall and the range. To visually check,

remove the range drawer.
Use pipe-joint compound made for use with Natural and

LP/Propane gas

to seal all gas

connections.

If flexible

connectors

are used,

be certain

connectors are

not kinked.

All connections must be wrench-tightened

Figure 10

Flare

Union

Flare

Union

GAS FLOW

Manual

Shutoff

Valve

Pressure

Regulator

On

Off

Flexible

Connector

Access

Cap

Nipple

Nipple

Shutoff Valve -

Open position

to appliance

to gas suppl

y line

Figure 11

The supply line must be equipped with an approved
manual shutoff valve. This valve should be located in
the same room as the range and should be in a location
that allows ease of opening and closing. Do not block
access to the shutoff valve. The valve is for turning on or
shutting off gas to the appliance.
Once regulator is in place, open the shutoff valve in the
gas supply line. Wait a few minutes for gas to move
through the gas line.
Leak testing of the appliance shall be conducted

according to the manufacturer's instructions.
Check for leaks.
After connecting the range to the gas

supply, check the system for leaks with a manometer. If

a manometer is not available, turn on the gas supply and

use a liquid leak detector at all joints and connections to

check for leaks.

Do not use a flame to check for leaks

from gas connections. Checking for leaks with a flame

may result in a fire or explosion.
All openings in the wall or floor where the range is to be

installed must be sealed.
Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.
Disconnect this range and its individual shutoff
valve
from the gas supply piping system during any
pressure testing of the system at test pressures greater
than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).
Isolate the range from the gas supply piping system
by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa or
14"(35,56 cm) water column).

7

LP/Propane Gas Conversion

This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.

If you wish to convert your range for use with LP/
Propane gas, use the supplied fixed orifices located in a
bag containing the literature marked "FOR LP/PROPANE
GAS CONVERSION." Follow the instructions packaged
with the orifices.

The conversion must be performed by a qualified service
technician in accordance with the manufacturer's
instructions and all local codes and requirements. Failure
to follow these instructions could result in serious injury
or property damage. The qualified agency performing
this work assumes responsibility for the conversion.

Failure to make the appropriate

conversion can result in personal injury and property
damage.

PRESSURE REGULATOR LOCATION

Figure 9

Advertising
This manual is related to the following products: