Freestanding Ranges

FGGF301DN F/ W/ B

30" Gas

Freestanding Range Specifications

Product Shipping Weight (approx.) – 260 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amp

Connected Load (kW Rating) @ 120 Volts = 1.8 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded

for safe operation.)

Amps @ 120 Volts = 15 Amps

Always consult local and national electric and gas codes.

Make sure wall coverings around range can withstand heat generated

by range.

Linoleum or any other synthetic floor covering located beneath range,

must be capable of withstanding minimum heat of 90° F above room

temperature without shrinking, warping or discoloring. Insulating pad

or 1/4"-thick plywood required between range and a carpeted floor.

Do not obstruct flow of combustion air at oven vent nor around base

or beneath lower front panel of range. Range requires fresh air for

proper burner combustion.

Do not install range beneath any downward-blowing, overhead vent

hood or air curtain.

Range ships with 1/2" NPT factory regulator.

Range is LP Gas convertible. (Optional LP Gas Conversion

Kit available.)

Overhead cabinetry should not exceed a 13" maximum depth.

Allow 30" minimum clearance between top of cooking surface and

bottom of unprotected wood or metal overhead cabinet; or 24"

minimum clearance when bottom of wood or metal overhead cabinet

is protected by not less than 1/4" flame-retardant millboard covered

with not less than No. 28 MSG sheet steel, 0.015" stainless steel,

0.024" aluminum or 0.020" copper.

Absolute minimum horizontal distance between overhead cabinets

installed to either side of appliance must be no less than maximum

width of appliance.

Range can be installed flush to wall with 0" minimum rear clearance.

Minimum 7" clearance required from edge of rangetop to nearest

combustible wall on either side of range above 36" height.

To reduce risk of fire when using overhead cabinetry, install vent hood

that projects horizontally a recommended minimum of 5" beyond

bottom of cabinets.

Follow all dimension requirements provided to prevent property

damage, potential fire hazard, and incorrect countertop and

cabinet cuts.

Optional Accessories

LP Gas Conversion Kit – (PN # 318565419)

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.