Operating instructions – FRIGIDAIRE FFRA0522Q1 User Manual

Page 8

Advertising
background image

8

Operating Instructions

Operating Instructions

(continued)

FAULT CODES

ADDITIONAL THINGS YOU SHOULD KNOW

If the display reads "AS",
a sensor has failed. Contact
your Authorized Frigidaire
Service Center.

Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.

The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly.
This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue
to run during this time.

The control will maintain the set temperature within 2 degrees Fahrenheit, between 60F and 90F degrees.

Air Directional Louvers

Air directional louvers control air flow direction. Your air conditioner has the louver
type described below.

Auger Type

Rotate the Auger Wheel until the desired Left/Right direction is obtained.

There is a 2-Second delay for the compressor shutting down when selecting FAN ONLY. This is to cover the possibility of having
to roll through to select another mode.

TO TURN UNlT OFF:

DO THIS:

PRESS ON/
OFF BUTTON

2009 Electrolux Home Products, Inc.

All rights reserved.

After a power outage, the unit will memorize the last setting and return the unit to the same setting once power is restored.

AUGER WHEEL

(2-WAY)

Note: The control is capable of displaying temperature
in degrees Fahrenheit or degrees Celsius.

TO CHANGE TEMPERATURE DISPLAY:

YOU WILL SEE:

DO THIS:

PRESS AND HOLD

THE UP/DOWN

BUTTONS TOGETHER

FOR 3 SECONDS

Note: If the unit is turned off in heat mode
(if applicable) or fan only mode, it will return
to the same setting when it is turned on again.
When the unit is turned off in cool or energy
saver mode, it will run in energy saver mode.
when it is turned on again, but the setting of
temperature and fan speed will remain.

Advertising