30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

(Models with an Electric Oven and a Gas Cooktop)

Direct Electrical Connection to the Circuit

Breaker, Fuse Box or Junction Box

If the appliance is connected directly to the circuit

breaker, fuse box or junction box, use flexible, armored

or nonmetallic sheathed copper cable (with grounding

wire). Supply a U.L. listed strain-relief at each end of

the cable. At the appliance end, the cable goes through

the Direct Connection Hole (see Figure 5) on the

Cord Mounting Plate. Wire sizes

(copper wire only)

and connections must conform to the rating of the

appliance. A 50A time-delay fuse or circuit breaker is

recommended (minimum 40A).
Where local codes permit connecting the

appliance-grounding conductor to the neutral

(white) wire (see Figure 5):

1. Be sure that no power is supplied on the cable from

residence.

2. Remove the grounding strap from the terminal block

and from the appliance frame.

3. In the circuit breaker, fuse box or junction box:

a) Connect the green (or bare copper) wire, the

white appliance cable wire, and the neutral (white)

wire together.

b) Connect the 2 black wires together.

c) Connect the 2 red wires together.

Figure 5

3-Wire (Grounded Neutral) Electrical System

(Example: Junction Box)

Cable from Residence

Junction

Box

White Wire

U.L.-listed Conduit

Connector (or CSA

listed)

Cable from

Appliance

Green

(or Bare Copper)

Wire

Red

Wires

Neutral

(white) Wire

Black

Wires

NOTE: Be sure to remove the

supplied grounding strap.

Where local codes DO NOT permit connecting

the appliance-grounding conductor to the neutral

(white) wire, or if connecting to 4-wire electrical

system (see Figure 6):

1. Be sure that no power is supplied on the cable

from residence.

2. Remove the grounding strap from the terminal

block and from the appliance frame.

3. In the circuit breaker, fuse box or junction box:

a) Connect the white appliance cable wire to the

neutral (white) wire.

b) Connect the 2 black wires together.

c) Connect the 2 red wires together.

d) Connect the green (or bare copper) grounding

wire to the grounding wire of the circuit breaker,

fuse box or junction box.

NOTE: Be sure to remove the

supplied grounding strap.

U.L.-listed Conduit

Connector (or CSA

listed)

Figure 6 – 4-Wire Electrical System

(Example: Junction Box)

Cable from Residence

Black

Wires

Junction

Box

White Wire

Cable from

Appliance

Green (or Bare

Copper) Wire

Red

Wires

White Wire

Green (or Bare

Copper) Wire

5

Cabinet Construction

To eliminate the risk of burns or fire

by reaching over heated surface units, do not have

cabinet storage space above the range. If there is

cabinet storage space above range, reduce risk by

installing a range hood that projects horizontally a

minimum of 5" (12,7 cm) beyond the bottom of the

cabinet.

Countertop Preparation

• The cooktop sides of the range fit over the cutout

edge of your countertop.

• If you have a

square finish (flat) countertop, no

countertop preparation is required. Cooktop sides lay

directly on edge of countertop.

• Formed front-edged countertops must have

molded edge shaved flat 3/4" (1,9 cm) from each

front corner of opening (Figure 7).