Specifications

subject to change.

Downdraft Vent

FH30DD50M S

30" In-Cabinet

30" Downdraft Vent - (FH30DD50MS)

Frigidaire Baseline

Downdraft Vent Specifications

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.41 kW (For use on

adequately wired 120V, dedicated circuit having 2-wire service with a

separate ground wire. Appliance must be grounded for safe operation.)

Amps @ 120 Volts = 3.4 Amps

Do not use same circuit as cooktop.

Always consult local and national electric codes. Check local building

codes for installation requirements, as they may vary per locale.

Locate grounded electrical outlet for 28"- long power cord within

reachable distance. When installing vent in 30"- wide cabinet, outlet

cannot be located on back wall of cabinet, but can be wall-mounted

with access hole in cabinet.

Downdraft Vent designed for installation with cooktop in island,

peninsula or conventional installation. (Cutout template provided,

packed with vent.)

To ensure proper installation with cooktop, refer to model-specific

cooktop installation guide on web for dimensions, countertop

cutout dimensions and cabinet requirements; oversized cabinets

recommended for ease of installation. Due to varying cooktop depths,

tight fit is possible between cooktop and vent, depending on overall

depth of countertop.

Pre-formed countertops with raised lip and /or backsplash may not

allow enough flat area for proper installation. Minimum 2-5/16" of flat

countertop required behind cooktop and 2-1/16" necessary between

back edge of cooktop and inside of cabinet back.

To ensure adequate clearance for air vent when raised /lowered, 1/8"

gap needed between back edge of cooktop and front of downdraft

top trim.

Vent exhaust air outside only.

Exhaust Duct Required – Galvanized or aluminum duct in 6" round

or 3-1/4" x 10" rectangular, or combination of both. PVC should

be used if installing under concrete slab.

Three blower discharge direction options available; rotate blower

motor for left, right or down discharge.

Consider ductwork location before cutting hole in cabinet. Blower

motor mounted on slide plate, enabling 3-1/2" left or right adjustment

to avoid duct interference with joists or other obstructions.

For maximum efficiency, use shortest and straightest duct run

possible. System operates most efficiently with up to 60 equivalent

feet of duct; Downdraft Vent operates properly with ductwork

up to 100 equivalent feet. (Refer to Calculating Duct Length Table

in Product Installation Guide.)

Do not use flexible duct. Round duct instead of rectangular duct

recommended, especially when elbows are required.

Thermal breaks such as short section of nonmetallic duct, should

be used in areas of extreme cold. Cold weather installations should

have additional backdraft damper installed.

High level of airflow may affect gas flame on some gas cooktop

models.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Accessories information available

on the web at

frigidaire.com