I/p vent hood fhpc3660ls, Glass canopy island hood – FRIGIDAIRE FHPC3660LS User Manual

Page 2

Advertising
background image

Accessories information available

on the web at

frigidaire.com

Glass Canopy Island Hood

FHPC3660L S

36" Stainless Steel

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-800-FRIGIDAIRE

frigidaire.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

frigidaire.ca

FHPC3660L 02/12

© 2012 Electrolux Home Products, Inc.

Specifications

subject to change.

Glass Canopy Island Hood Specifications

Product Shipping Weight (approx.) – 88 Lbs.

Island / Peninsula Ceiling-Mount Installation

Ventilation system is preset to exhaust air outside. If outside

ducting is not possible, optional Duct-Free Recirculation Kit

(PN # FHPRKT60LS) is available to convert ventilation to allow air

to recirculate inside. (Refer to Ducted Option Specifications for

outside ventilation.)

Sones Rating – 6.5

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.52 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded

for safe operation.)

Amps @ 120 Volts = 4 Amps

Always consult local and national electric codes. Check local building

codes for installation requirements, as they may vary per locale.

Minimum installation height allowed from bottom of hood to standard

36"-high electric or gas cooking surface is 24" - 36". (NOT more than

32" recommended.) For detailed instructions regarding install heights

in 8', 9' and 10' ceiling applications, refer to installation guide on web.

To prepare mounting surface, adequate structure and support must

be provided, capable of supporting 150 lbs.

Ducted Option Specifications

For outside ventilation.

Exhaust Duct Required – 6" round

For most efficient airflow exhaust, use a straight run or as few

elbows as possible.

Use metallic flex ducting only to connect rigid duct directly to

transitions (if allowed by code).

Thermal breaks such as short section of nonmetallic duct, should

be used in areas of extreme cold.

Cold weather installations should have additional backdraft damper

installed.

Refer to installation instructions on web for detailed exhaust duct

preparation and converting vent blower system for recirculating inside.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Pre-Installation Calculations

Select hood preference height (P) that is comfortable for user

(24" - 36" minimum allowed, NOT more than 32" recommended).

Calculate hood height (H) for installation (H = K-C-P).

Confirm that (H) is within minimum to maximum range for hood. If

not, adjust installation.

Calculate chimney structure height (S). Use formulas, check

dimensions of hood. Save calculation for use later in installation.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

Duct-Free Recirculation Kit – (PN # FHPRKT60LS).

10' Flue Extension Kit – (PN # FHP10X60LS).

I/P Vent Hood

FHPC3660LS