36 " GAS RANGE INSTALLATION INSTRUCTIONS

3

3. Seal the openings

Seal any openings in the wall behind the range and

in the floor under the range after gas supply line is

installed.

4. Connect the range to the gas

supply

oven burner and broil burner on your range

are lighted by electrical ignition. The oven and

broiler cannot be operated in the event of a

power failure.

• In the event of an electrical power outage, the

surface burners can be lit manually. To light a

surface burner, hold a lit match to the burner head

and slowly turn the Surface Control knob to LITE.

Use caution when lighting surface burners manually.

• Reset all controls to the "off" position

whenever the oven is done cooking.

FOR MODELS WITH SELF-CLEAN FEATURE:

• Remove broiler pan, food and other utensils

before self-cleaning the oven. Wipe up excess

spillage. Follow the precleaning instructions in the

Use and Care Guide.

• Unlike the standard gas range, THIS COOKTOP

IS NOT REMOVABLE. Do not attempt to remove

the cooktop.

1. Before Installing the Range

Remove shipping material

Remove all tape, shipping and packaging materials and

the oven rack packaging.

2. Provide an adequate Gas Supply

When shipped from the factory, this unit is designed

to operate on 4"(10,16 cm) water column (1.0 kPa)

Natural gas manifold pressure. A convertible pressure

regulator is connected to the range manifold and

MUST be connected in series with the gas supply line.

If LP/Propane conversion kit has been used, follow

instructions provided with the kit for converting the

pressure regulator to LP/Propane use.

Care must be taken during installation of range not to

obstruct the flow of air for combustion and ventilation.

For proper operation, the maximum inlet pressure

to the regulator should be no more than 14"(35,56

cm) of water column pressure (3.5 kPa). The inlet

pressure to the regulator must be at least 1" (.25 kPa)

greater than the regulator manifold pressure setting.

Examples: If regulator is set for natural gas 4"(10,16

cm) manifold pressure, inlet pressure must be at least

5"(12.60 cm); if regulator has been converted for LP/

Propane gas 10"(25,4 cm) manifold pressure, inlet

pressure must be at least 11"(27,9 cm).

Leak testing of the appliance shall be conducted

according to the instructions in step 4.

The gas supply line should be ½" or ¾" I.D. (Interior

Diameter)

Figure 2

Pressure

Regulator

Location

Assemble the flexible connector from the gas supply

pipe to the pressure regulator in the following order:

1. manual shutoff valve (not included)

2. 1/2" nipple (not included)

3. 1/2" flare union adapter (not included)

4. flexible connector (not included)

5. 1/2" flare union adapter (not included)

6. 1/2" nipple (not included)

7. pressure regulator (Included)

All connections must be wrench-tightened

Figure 3

Flare

Union

Flare

Union

GAS FLOW

Manual

Shutoff

Valve

Pressure

Regulator

On

Off

Flexible

Connector

Access

Cap

Nipple

Nipple

Important:

Remove

all packing material and

literature from range before

connecting gas and electrical

supply.
To prevent leaks, put pipe

joint sealant on all external

pipe threads.
Your regulator is in location

shown below.

Do not

allow regulator to rotate

on pipe when tightening

fittings.

Connection to Pressure Regulator

The regulator is already installed on the appliance.

Do not make the connection too

tight. The regulator is die cast. Overtightening may

crack the regulator resulting in a gas leak and possible

fire or explosion.