Home comfort – FRIGIDAIRE FRS22PYS2 User Manual

Page 2

Advertising
background image

Model Numbers

System Model Number
Indoor Unit Part Number
Outdoor Unit Part Number

1

Performance

BTU (Cool)
BTU (Heat Pump)
Cooling Area (Sq. Ft.)
SEER (Air Conditioner)
HSPF (Heat Pump)
Inverter Technology

Electrical

Volts
Amps (Cool) Indoor/Outdoor
Watts (Cool) Indoor/Outdoor
Amps (Heat) Indoor/Outdoor
Watts (Heat) Indoor/Outdoor
Fuse (Amps) Indoor/Outdoor

Features

Controls
Fan Speeds (Cool/Fan/Heat)
Low Voltage Start-Up
Turbo Fan
Auto Fan
Energy Saver
Sleep Mode
24 Hour On/Off Timer
Remote Control
Air CFM (High/Med/Low) Indoor
Air Direction Control (Vert. / Horz.)
Air Discharge (Full-Width)
Filter Type
Filter Access
Air Direction Control - Horizontal
Air Direction Control - Vertical
dB (Indoor) (High/Med/Low)
dB (Outdoor)
Warranty

2

Included Accessories

Drain Kit (Outdoor Unit)
Installation Plate (Indoor Unit)
Line Set (Indoor Unit)
Remote Holder (Indoor Unit)

Certifications

ENERGY STAR®
Performance

Specifications

Refrigerant
Shipping Weight (Approx.)

Home Comfort

FRS22PYS2

Ductless Mini-Split Air Conditioner / Heat Pump

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-800-FRIGIDAIRE

frigidaire.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

frigidaire.ca

FRS22PYS2 06/11

© 2011 Electrolux Home Products, Inc.

Printed in the U.S.A.

Specifications

subject to change.

FRS22PYS2
FRS22PYW2
FRS22PYC2

21,500
26,600
1,430
18
10.2
Yes

230 / 208
0.5 / 7.9
38 / 1,835 (320-2,530)
0.5 / 12.3
38 / 2,800 (340-2,800)
3.15 / 25

Ready-Select® Controls
4 / 3 / 4
Yes
Yes
Yes
Yes
Yes
Yes
Full-Function
276 / 242 / 107
Yes / Yes
Bottom
Antimicrobial Mesh
Slide-Out
Manual
Swing
44 / 40 / 35
56
Yes

Yes
Yes
Yes
Yes

Yes
ARI

R410a
132

1

Includes 16.4 ft. line set.

2

Warranty 5 year sealed system / 1 year full parts and labor.

1

Illustration may not represent actual model.

All refrigeration and electrical work must be performed by a certified and licensed

refrigeration technician for full parts and labor warranty validation. Insulated line sets

and control wires are required and available for Frigidaire split systems in 16.4 ft.

length. Each line set is equipped with flare nuts on both ends. Each system requires

one line set for each indoor unit installed.

NOTE: For planning purposes only. Always consult local and

national electric codes. Refer to Product Installation Guide for

detailed installation instructions on the web at frigidaire.com.

Product Dimensions

Indoor –
A - Height
B - Width
C - Depth
Max. Wall Thickness
Outdoor –
A - Height
B - Width
C - Depth

12-7/16"
39-11/16"
8-7/8"
18"

31-1/8"
36-1/4"
14-5/8"

RAC Indoor/Outdoor Ductless Heat Pump Split Models

Frigidaire Baseline

B

A

C

A

B

C

FRS22PYC2

1

Outdoor

FRS22PYW2

1

Indoor

Accessories information available

on the web at

frigidaire.com

Advertising